background image

4

31-5000516   Rev. 3

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

READ AND SAVE THESE INSTRUCTIONS

WARNING

For your safety, the information in this manual must be followed to minimize the risk of fire, 

electric shock, or personal injury.

•  Use this equipment only for its intended purpose as 

described in this manual. 

•  This heat pump must be properly installed in 

accordance with these instructions before it is used.

•  All wiring should be rated for the amperage value listed 

on the rating plate.  Use only copper wiring. 

•  All electrical work must be completed by a qualified 

electrician and completed in accordance with local and 
national building codes.

•  Any servicing must be performed by a qualified 

individual. GE Appliances/Haier recommends factory 
trained and service & installation contractors that meet 
local and national code requirements for the region.

•  All air conditioners contain refrigerants, which under 

federal law must be removed prior to product disposal. 
If you are disposing of an old product with refrigerants, 
check with the company handling disposal. 

•  These R-410A heat pumps systems require that 

contractors and technicians use tools, equipment and 
safety standards approved for use with this refrigerant. 
DO NOT use equipment certified for R22 refrigerant 
only.

WARNING

RISK OF ELECTRIC SHOCK. Could cause injury or death.

•  An adequate ground is essential before connecting the 

power supply.

•   Disconnect all connected electric power supplies before 

servicing.

•  Repair or replace immediately all electrical wiring that 

has become frayed or otherwise damaged.  Do not use 
wiring that shows cracks or abrasion damage along its 
length or at either end.

WARNING

 

RISK OF FIRE. Could cause injury or death.

•  Do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any 

other appliance.

WARNING

 

-  This product is not intended for use by persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.

- Children should be supervised to ensure that they do not play with the product

- Ensure that the unit shall be installed in accordance with local and national wiring codes 

-  Ensure the dimensions of the space necessary for correct installation of the appliance including the minimum 

permissible distances to adjacent structures

-  Ensure only approved units are connected together and that all refrigerant line dimensions and refrigerant charging 

requirements are followed to prevent exceeding the maximum operating pressure

-  ONLY connect units that are labeled with the same refrigerant.

-  Any damage of electrical supply must be replaced by the manufacturer, its service agent or similarly qualified persons 

in order to avoid a hazard.

For any service which requires entry into the 
refrigerant sealed system, Federal regulations 
require that the work is performed by a technician 
having a Class II or Universal certification.

Содержание GE APPLIANCES USYL24UCDDA

Страница 1: ...ancesairandwater com L aspect peut varier selon le num ro de mod le Ce manuel d installation est uniquement imprim en anglais Pour la version fran aise ou espagnole visitez le site GEAppliancesairandw...

Страница 2: ...2 31 5000516 Rev 3 This manual contains installation instructions for Large Cassette indoor units...

Страница 3: ...l on the side of your air conditioner heat pump and the date of purchase Staple your proof of purchase to this manual to aid in obtaining warranty service if needed ___________________________________...

Страница 4: ...all connected electric power supplies before servicing Repair or replace immediately all electrical wiring that has become frayed or otherwise damaged Do not use wiring that shows cracks or abrasion d...

Страница 5: ...Cooling Capacity Btu hr 24 000 30 000 36 000 42 000 47 000 Rated Heating Capacity Btu hr 26 000 31 000 37 000 44 000 47 000 Voltage Cycle Phase V Hz 208 230 60 1 208 230 60 1 208 230 60 1 208 230 60...

Страница 6: ...installation contractors that meet local and national code requirements for the region Use team lift for mounting the ducted unit Proper installation is the responsibility of the installer Product fa...

Страница 7: ...ting tube Clamp Flare nuts Insulation Mounting Template Model Liquid in Vapor in USYL24UCDDA 3 8 5 8 USYL30UCDDA 3 4 USYL36UCDDA USYL42UCDDA USYL48UCDDA Insulated copper tubing 14 4 14 gauge 4 conduct...

Страница 8: ...etween TV Radio or any communication wiring and the power to the indoor unit 14 4 non shielded stranded copper cable wire should be used to make the electrical connection and communication link betwee...

Страница 9: ...to position the unit Place where the drainage pipe can be properly positioned Place where the inlet and outlet air of the indoor unit will not be blocked Do not install the unit in a place with heavy...

Страница 10: ...sette and position the threaded rods into the 4 mounting clips on each corner of the cassette unit One Inch Recess 1 25mm recess between ceiling surface and bottom of unit without panel on 1 25 B Thre...

Страница 11: ...the flexible hose to the building s condensate drain system E Prior to routing the refrigerant lines to the unit install the supplied flare nuts onto the refrigerant lines Using an R 410 flaring tool...

Страница 12: ...6 After downloading the App 2 Open the app 3 Select Sign In 4 Sign into your account or register as a new user 5 Select the icon to add a new device and follow the directions in the app Step 2 Install...

Страница 13: ...art by GE Appliances a Haier company e g a used and or unapproved condenser air handler Component or parts are not provided by GE Appliances a Haier Company Product that has been moved from its origin...

Страница 14: ...hases will receive the remainder of the Standard Base Warranty The remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or...

Страница 15: ...WH DSSRVpH VXU OH F Wp GH YRWUH WKHUPRSRPSH DYHF OD GDWH GH O DFKDW URFKH YRWUH SUHXYH G DFKDW VXU FH PDQXHO SRXU IDFLOLWHU OH VHUYLFH VRXV JDUDQWLH OH FDV pFKpDQW ___________________________________...

Страница 16: ...ne r paration ou un entretien 5pSDUH RX UHPSODFH LPPpGLDWHPHQW WRXW FkEODJH pOHFWULTXH XVp RX DXWUHPHQW HQGRPPDJp 1 XWLOLVH SDV XQ FkEODJH TXL SUpVHQWH GHV ILVVXUHV RX GHV PDUTXHV G DEUDVLRQ VXU VD OR...

Страница 17: ...HULH GH UpIULJpUDQW j O LQWpULHXU GH O DSSDUHLO SRXU pYLWHU OD FRQGHQVDWLRQ d eau Int rieur USYL24UCDDA 86 8 USYL36UCDDA USYL42UCDDA USYL48UCDDA DSDFLWp GH UHIURLGLVVHPHQW QRPLQDO WX K DSDFLWp GH FKDX...

Страница 18: ...QDWLRQDX SRXU OD UpJLRQ 8WLOLVH OH OqYH SHUVRQQH SRXU PRQWHU O XQLWp FDQDOLVpH H DFWLWXGH GH O LQVWDOODWLRQ HVW OD UHVSRQVDELOLWp GH l installateur D JDUDQWLH QH FRXYUH SDV OHV GpIHFWXRVLWpV GX SURGXL...

Страница 19: ...GDSWDWHXU PLQL VSOLW SR j SR 0 RWH SURGXLW FRQVRPPDEOH RXSH WXEH Couteau utilitaire Al soir 6FHOODQW QRQ H SDQVLI SRXU WURX GH WXEXOXUH 6ROXWLRQ G HDX VDYRQQHXVH RX GpWHFWHXU GH IXLWH GH JD RFDOLVDWH...

Страница 20: ...n below Alimentation lectrique 6XLYH WRXV OHV FRGHV HW UqJOHPHQWV ORFDX ORUVTXH YRXV LQVWDOOH OH FkEODJH pOHFWULTXH FKHPLQH O DOLPHQWDWLRQ pOHFWULTXH UHTXLVH YHUV OD RQH R O XQLWp j FDVVHWWH HVW VLWXp...

Страница 21: ...GHVVXV GX SODIRQG RX GDQV OD RQH GH VRIILWH R LO D VXIILVDPPHQW G HVSDFH SRXU OD placer 3ODFH O XQLWp Oj R OH WX DX G pYDFXDWLRQ SHXW rWUH LQVWDOOp DGpTXDWHPHQW 3ODFH O XQLWp Oj R O DLU G HQWUpH HW G...

Страница 22: ...RLWLHU HW SODFH OHV WLJHV ILOHWpHV GDQV OHV TXDWUH EULGHV GH IL DWLRQ j FKDTXH FRLQ GX ERLWLHU Enfoncement de 25 mm 1 po QIRQFHPHQW GH SR PP HQWUH OD VXUIDFH GX SODIRQG HW OH EDV GH O DSSDUHLO VDQV VR...

Страница 23: ...j O DVVHPEODJH G pYHQW j ODPHV F 5DFFRUGH OH ER DX IOH LEOH GH GUDLQDJH JULV IRXUQL DYHF OH ERLWLHU DX ER DX GH YLGDQJH GH OD SRPSH j FRQGHQVDW GX ERLWLHU 6HUUH IHUPHPHQW OH FROOLHU 8WLOLVH OH ER DX...

Страница 24: ...ieur et ext rieur kEOH HQ FXLYUH WRURQQp VDQV EOLQGDJH VHXOHPHQW 0DLQWHQLU XQH GLVWDQFH GH SLHGV GH VpSDUDWLRQ HQWUH WRXW FkEODJH GH WpOpYLVHXU HW GH UDGLR REMARQUE 1 XWLOLVH SDV GH FRVVHV REMARQUE 6H...

Страница 25: ...W OHV VHUYLFHV FRQQH HV SRXU OD UpSDUDWLRQ RX l installation du Produit 8Q 3URGXLW DFKHWp DXSUqV G XQ UHYHQGHXU HQ OLJQH QRQ DXWRULVp HV GRPPDJHV UpVXOWDQW GH O H SRVLWLRQ GX 3URGXLW j XQH DWPRVSKqUH...

Страница 26: ...e s applique pour la garantie limit e sur les pi ces Sauf au Texas ou aux endroits o la loi l exige cette garantie limit e enregistr e standard n est pas transf rable un acheteur subs quent autre que...

Страница 27: ...aire bomba de calor y la fecha de compra Abroche su comprobante de compra a este manual como ayuda para acceder al servicio de la garant a de ser necesario ____________________________________ N mero...

Страница 28: ...r la conexi n al suministro de corriente Desconecte todos los suministros de corriente el ctrica remotos antes de realizar el servicio t cnico Repare o reemplace de inmediato todos los cables de corri...

Страница 29: ...UCDDA Capacidad Nominal de Refrigeraci n en Btu hr 24 000 30 000 36 000 42 000 47 000 Capacidad Nominal de Calefacci n en Btu hr 26 000 31 000 37 000 44 000 47 000 Voltaje Ciclo Fase V HZ 208 230 60 1...

Страница 30: ...c digos local y nacional para la regi n Use el elevador de equipo para montar la unidad canalizada La correcta instalaci n del producto es responsabilidad del instalador Si se producen fallas en el pr...

Страница 31: ...Mini Split 5 16 F a 1 4 M Nitr geno consumible Cortatubos Cuchillo con Filo Escariador Sellador no expansible para el orificio del juego de cables Soluci n de jab n agua o detector de p rdidas de gas...

Страница 32: ...nidad tipo cassette 8 1 4 210 4 100 12 in below 3 5 ft 11 in under 8 6 in 8 6 in 9 6 in below Corriente El ctrica Cumpla con todos los c digos y regulaciones locales al instalar el cableado el ctrico...

Страница 33: ...el cielorraso o en un rea de sofito donde haya suficiente espacio para posicionar la unidad Colocar donde la tuber a de drenaje pueda ser posicionada correctamente Colocar donde el aire entrante y sa...

Страница 34: ...ipo cassette deber ser montada sobre la estructura de la edificaci n usando varillas roscadas Las varillas roscadas deber n contar con arandelas y tuercas a fin de permitir que la altura y el nivel de...

Страница 35: ...e de la rejilla F Conecte la manguera de desag e flexible gris suministrada con la unidad tipo cassette a la tuber a de descarga de la bomba de condensaci n de la unidad tipo cassette Ajuste la abraza...

Страница 36: ...TA Ajuste las terminales del conector al grado de torsi n del fabricante NOTA Si el cable que conecta la unidad Interior y Exterior 180 pies 55m el cable a tierra de la unidad interior se deber separa...

Страница 37: ...cnico no fue realizado por un t cnico con licencia de HVAC Trabajo o servicios relacionados con la reparaci n o instalaci n del Producto Un Producto comprado a un vendedor minorista no autorizado a tr...

Страница 38: ...en los Est ndares La soluci n provista en esta garant a es exclusiva y es garantizada en lugar de todas las dem s soluciones Esta garant a no cubre da os incidentales o consecuentes Algunos estados y...

Отзывы: