16
AD50S2SM1FA AD71S2SM1FA
Y/G:YELLOW/GREEN
NOTE: 1.DASHED P
AR
TS
ARE OPTIONAL.
2.SW03-4 IS
AT
ON POSITION,DO NOT
CHANGE
THE SETTINGS OF SWITCHS WITHOUT
GUIDANCE.
3.WHEN ONE WIRED CONTROLLER CONTROL
MUL
TIPLE INDOOR UNIT
,
IT
CAN CONNECT
ANOTHER INDOOR UNIT
BY
CN22 OR CN22-1.
WHEN
TWO WIRD CONTROLLERS CONTROL
ONE INDOOR UNIT
,
THE WIRED CONTROLLER NEED CONNECT
WITH CN22
AND CN22-1.
TEMP
.
SENSOR
ROOM
SENSOR
PIPING TEMP
.
ROOMCARD
R
O T
O
M
N
A F
C
D
SW03
FUSE
W
IRED
CONTROLLER
FLOA
T
SWITCH
WIFI MODULE
PUMP
TO OUT
DOOR
2
1
3
Y/G
M
12345678
ON
REMOTE RECEIVER
M
B
A
C
B
A
C
OFF
0150523302
2
1
3
N L S
B
A
C
SW01
12345678
ON OFF
FRESH
AIR MOT
OR
(SW01-6 select OFF) / EXTERNAL
ALARM
OUTPUT
(SW01-6 select ON) ( Contact rating_230V
AC,3A)
M
CN21
Heater_L
CH4
Heater_N
CH2
CN5
CN4
CN34
CN16
CH1
SW01-1
SW01-2
SW01-3
ON
SW01-4
SW01-5
SW01-6
SW01-7
SW01-8
MODEL
OFF
AM24LP2VHA
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
ADH071M3ERG
OFF
OFF
ON
CN13
CN6
CN41
CN22
CN22-1
4.SW03-5
->SW03-08 IS USED FOR
ADDRESS SETTING ON
THE
SITUA
TION OF ONE WIRED CONTROLLER CONTROL
MORE
THAN
ONE INDOOR UNIT
.
5.REFER
TO SER
VICE MANUL
T
O GET
MUCH MORE DET
AILS
ABOUT
THE ST
ATIC PRESSURE LEVEL
SELECTION.
CN1
AD71S2SM1F
A
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
AD50S2SM1F
A
SW03-1
SW03-2
SW03-3
FOR ALL
DUCTED
MODEL
SW03-4
SW03-5
SW03-6
SW03-7
SW03-8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Содержание AB25S2SC1FA
Страница 1: ...SYJS 04 2017 REV A Edition 2017 04 service manual R32...
Страница 3: ...1 Part 1 General Information 1 Indoor outdoor unit models 2 2 Feature 3...
Страница 14: ...12 AB25S2SC1FA AB35S2SC1FA AD25S2SC1FA AD35S2SC1FA 420 370 892 850 185 640 90 760 152 2 Dimension unit mm...
Страница 23: ...21 5 Installation For AB25S2SC1FA AB35S2SC1FA 1 Installation procedure...
Страница 24: ...22 AB25S2SC1FA AB35S2SC1FA AB25S2SC1FA AB35S2SC1FA...
Страница 25: ...23...
Страница 26: ...24...
Страница 27: ...25 AB25S2SC1FA AB35S2SC1FA...
Страница 28: ...26...
Страница 29: ...27 For AD25S2SC1FA AD35S2SC1FA Installation procedure AD25S2SS1FA AD35S2SS1FA...
Страница 30: ...28 AD25S2SS1FA AD35S2SS1FA AD25S2SS1FA AD35S2SS1FA...
Страница 31: ...29...
Страница 32: ...30 AD25S2SS1FA AD35S2SS1FA...
Страница 33: ...31...
Страница 38: ...36 21mm AD50S2SM1FA AD71S2SM1FA Unit model The size of drain opening...
Страница 39: ...37...
Страница 54: ...52 2 Dimension 1U71S2SM1FA 860 633 unit mm...
Страница 91: ...89 R32 R32 R32 R32 R32 R32 R32 R32 R32 10 2 Read before installation...
Страница 92: ...90 3 R32 R32 R32 R32 R32 R32 R32...
Страница 93: ...91 R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A...
Страница 96: ...94 10 5 Air tightness test...
Страница 97: ...95 R32 R32 10 6 Vacuuming...
Страница 123: ...121 PCB 0011800410RA 1U71S2SG1FA Power module 0011800377C 1U71S2SG1FA...
Страница 182: ...Haier Commercial Air Condition Web Http www haier com Haier reserves the right to make change without any notice...