160
Functional description
1. Power-up and Show All:
the LCD display shows all symbols in this function. 3s later, it
just shows time and the initial time is AM 12:00. The initial time
is adjustable and will be
automatically 10s later.
2. ON/OFF Button:
press the button for power on. The initial default mode is
SMART, otherwise it will be the mode before power OFF.
Press OFF button after power on.
3. SMART Button:
(1) SMART button is always valid during power ON/OFF;
(2) Press SMART button to execute power OFF in SMART
mode;
(3) In OFF and other modes, press SMART button to enter
initial default setting of SMART mode. LCD setting
temperature is not showed;
(4) In SMART mode, press TEMP. +/- button to show the
setting temperature.
4. COOL Button, HEAT Button and DRY Button
(1) When the remote controller in ON, press COOL button,
HEAT button and DRY button to execute COOL mode,
HEAT mode and DRY mode.
(2) For initial power-up, temperature and fan speed will be
showed as follows when entering each mode, otherwise
parameters set last time will be showed;
Mode SMART HEAT COOL DRY
FAN
Initial
TEMP.
24°C
24°C
24°C
24°C
Setting
temperature is
not showed.
Mode SMART HEAT COOL DRY
FAN
Initial Fan
Speed
AUTO
LOW
HI
AUTO
LOW
5. FAN Mode
(1) During power OFF, press “HEALTH” button or “FRESH”
button to enter FAN mode with low fan speed. Meanwhile,
the HEALTH or FRESH icon will be showed on the screen.
(2) Temperature is not showed in FAN mode.
(3) Auto fan speed is not available when switching fan speed
in FAN mode.
6. FAN SPEED Button:
(1) In other modes except for Fan mode, LOW, MED, HI and
AUTO fan speed is adjustable, switching sequence is as
LOW-MED-HI-AUTO-LOW.
LOW, MED and HI fan speed
circulate automatically
LOW
MED
HI
AUTO FAN SPEED
(2) After TURBO or QUIET is set. Press TURBO but-
ton to show
on the screen with fan speed as
, then press “FAN SPEED” button to exit;
press QUIET button to show
on the screen with fan
speed as
, then press “FAN SPEED” button to exit.
To cancel TURBO and QUIET, press TURBO and QUIET
buttons respectively,
and
icons will disap-
pear and the fan speed will return to the last one.
(3) This button is invalid during power OFF.
7. TEMP. +/- Button:
(1) This button is invalid in FAN mode;
(2) Temperature adjustment range in SMART, HEAT, COOL
and DRY mode: 16 ~30°C.
(3) Press and hold “TEMP. +/- “ button, the temperature chang-
es once; long press the button, the temperature changes
rapidly.
8. Four-side Embedment (Available for some models):
(1) Initial position of all modes for
power on:
SMART HEAT
COOL
DRY
FAN
Four-side
Embedment Show all Show all Show all Show all Show all
SWING Angle Position
3
Position
5
Position
3
Position
3
Position
3
(2) After power on, press “Four-side Embedment” button for
the
time and the recycle approach is as follows: four-
side simultaneous control of Four-side Embedment
→
Four-side Embedment 1
→
Four-side Embedment 2
→
Four-side Embedment 3
→
Four-side Embedment 4
→
Four-side simultaneous control of Four-side Embedment.
(3) When pressing “Four-side Embedment” button to select air
, the selected air
Press “Up-and-
down Angle” button to adjust angle of air
at the
moment.
9. Up-and-down SWING Angle:
1: Position 1; 2: Position 2; 3: Position 3;
4: Position 4; 5: Position 5; 6: Position 6 (reserved)
Recycle approach: Position
1→Position
2→Position
3
→Position
4→Position
5→AU
T
O→Position
1
Auto swing:
1→2→3→4→5→4→3→2→1
is showed circularly.
10. Right-and-left SWING Angle (Available for
some models):
Recycle approach: 34 showed (Position
1)→25
showed (Position
2)→16
showed (Position
3)→1
showed (Position
4)→2
showed (Position
5)→5
showed
(Position
6)→6
showed (Position
7)→Auto
swing
Auto swing approach:
1→2→3→4→5→6→5→4→3→2→1
are
showed circularly.
1
2
3
6 5
4
1 2 3
6
5
4
11. HEALTH AIRFLOW (Available for some models):
Press "HEALTH AIRFLOW" button to show icon on LCD
display. Each air
of swings on four sides alternates
circularly to indicate that the swing rotates to exhaust air.
Meanwhile, up-and-down SWING angle shows AUTO SWING.
Press it again to cancel HEALTH AIRFLOW.
Show 1s
Show 1s
Show 1s
Show 1s
Show 1s
12. SLEEP:
(1) Valid during power on.
(2) The SLEEP time is
to 8 hours and is not adjustable.
(3) It is invalid in FAN mode. When setting TIMER ON or
TIMER ON to TIMER OFF after setting SLEEP function,
once the timer setting is successful, the SLEEP function
will be cancelled; after setting TIMER ON or TIMER ON to
TIMER OFF, the SLEEP function cannot be set. SLEEP
function can be set from TIMER OFF to TIMER ON, TIMER
OFF and SLEEP function have priority in canceling the
opposite side.
13. HEALTH:
(1) During power-on or power-OFF, press “HEALTH” button to
display icon on LCD display, and press “HEALTH” button
again to cancel.
(2) During power-OFF, press “HEALTH” button to enter Fan
mode, start low wind and HEALTH function, display icon
(3) Switch among modes, and keep HEALTH function.
(4) If HEALTH function is set, power OFF and then on to stay
in HEALTH mode.
Содержание AB25S2SC1FA
Страница 1: ...SYJS 04 2017 REV A Edition 2017 04 service manual R32...
Страница 3: ...1 Part 1 General Information 1 Indoor outdoor unit models 2 2 Feature 3...
Страница 14: ...12 AB25S2SC1FA AB35S2SC1FA AD25S2SC1FA AD35S2SC1FA 420 370 892 850 185 640 90 760 152 2 Dimension unit mm...
Страница 23: ...21 5 Installation For AB25S2SC1FA AB35S2SC1FA 1 Installation procedure...
Страница 24: ...22 AB25S2SC1FA AB35S2SC1FA AB25S2SC1FA AB35S2SC1FA...
Страница 25: ...23...
Страница 26: ...24...
Страница 27: ...25 AB25S2SC1FA AB35S2SC1FA...
Страница 28: ...26...
Страница 29: ...27 For AD25S2SC1FA AD35S2SC1FA Installation procedure AD25S2SS1FA AD35S2SS1FA...
Страница 30: ...28 AD25S2SS1FA AD35S2SS1FA AD25S2SS1FA AD35S2SS1FA...
Страница 31: ...29...
Страница 32: ...30 AD25S2SS1FA AD35S2SS1FA...
Страница 33: ...31...
Страница 38: ...36 21mm AD50S2SM1FA AD71S2SM1FA Unit model The size of drain opening...
Страница 39: ...37...
Страница 54: ...52 2 Dimension 1U71S2SM1FA 860 633 unit mm...
Страница 91: ...89 R32 R32 R32 R32 R32 R32 R32 R32 R32 10 2 Read before installation...
Страница 92: ...90 3 R32 R32 R32 R32 R32 R32 R32...
Страница 93: ...91 R32 R32 R32 R32 R32 R32 R32 R32 10A HFC 410A...
Страница 96: ...94 10 5 Air tightness test...
Страница 97: ...95 R32 R32 10 6 Vacuuming...
Страница 123: ...121 PCB 0011800410RA 1U71S2SG1FA Power module 0011800377C 1U71S2SG1FA...
Страница 182: ...Haier Commercial Air Condition Web Http www haier com Haier reserves the right to make change without any notice...