Operation
Sleep Operation
5.Fan Speed in Sleep Mode
When the unit is set to sleep mode, the fan speed
will be set to low speed and it cannot be changed.
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts
SLEEP operation stops
SLEEP
operation starts
SLEEP
operation stops
Approx.6hrs
1 hr
1 hr
1 hr
3 hrs
3 hrs
Rises 1
O
C/ 2 F
Rises 1
O
C/ 2 F
Rises 1
O
C/ 2 F
Temp.setting
Temp.setting
Unit stop
Unit stop
In COOL, DRY mode
In HEAT mode
Decreases 2
O
C/ 4 F
Decreases 2
O
C/ 4 F
1 hr
2.
3.
In HEAT mode
In AUTO mode
4. In FAN mode
It has no SLEEP function.
Note
When TIMER function is set, the sleep function can’t be
set up .After the sleep function is set up, if user set up
TIMER function, the sleep function will be cancelled; the
machine will be in the state of timing-on.
Power/Quiet Operation
1 hour after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hour,temp.rises
by 1 / 2 F futher. The unit will run for an additional 6
hours then stops Temp. is higher than temp.setting so
that room temperature won’t be too low for your sleep.
1 hour after SLEEP mode starts,temp will become 2
4 F lower than temp.setting.After another 1 hour,temp
decrease by 2
C / 4 F futher.After more another 3 hours,
temp.
rises by 1
C / 2 F
futher.The unit will run for an
additional 3 hours then stops.Temp.is lower than temp.
setting so that room temperature won’t be too high for
your sleep.
If the unit is running cooling, the sleep mode will follow
the function as in cool mode, while follow as in heat mode.
O
C
O
O
1
O
C/2 F
O
C /
Press button to enter additional options, cycle
the display to , will flash. And then press
enter for sleep function.
(1)
Power Operation
(2)
Quiet Operation
Note
When you need rapid heating or cooling, you can use this function.
You can use this function when silence is needed for rest or
Running the unit in QUIET mode for a long period may
cause the room temperature to not reach the set
temperature. If this occurs, cancel QUITE mode and set
the fan speed to a higher setting.
reading.Press QUIET button, the remote controller will show
, and then achieve to the quiet function. To cancel this
function, press the QUIET button.
Press button to enter additional options, cycle the
display to , will flash
,
and then press ,enter to
power function. To cancel this function, please select a
different option.
3
O
O
O
O
O
O
O
O
O
O
Содержание 2HUM18HC003
Страница 2: ......
Страница 11: ...Removal of procedure 1 Removal of Air Filter 1 Domestic Air Condition ...
Страница 14: ...Removal of procedure three two HOOKS 4 Domestic Air Condition ...
Страница 15: ...Removal of procedure 3 Removal of horizontal flap flap flap flap flap 5 Domestic Air Condition ...
Страница 16: ...Removal of procedure 4 Removal of Drain pan 6 Domestic Air Condition ...
Страница 17: ...Removal of procedure 5 Removal of vertical blades and swing motor 7 Domestic Air Condition ...
Страница 18: ...Removal of procedure 6 Removal of Electrical Box 8 Domestic Air Condition ...
Страница 19: ...Removal of procedure 7 Removal of Heat Exchanger 9 Domestic Air Condition ...
Страница 20: ...Removal of procedure 10 Domestic Air Condition ...
Страница 21: ...Removal of procedure 8 Removal of Fan Rotor and Motor 11 Domestic Air Condition ...
Страница 22: ...Removal of procedure 12 Domestic Air Condition ...