background image

Operation

1.After unit starts, select your desired operation mode.

2.Press TIMER button to change TIMER mode. Every

time the button is pressed, display changes as follows:

Remote controller:

BLANK

TIMER ON

TIMER OFF

TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON or

TIMER OFF or TIMER ON-OFF). "        "or "       "will flash.

3.Press        /

button to set time.

It can be adjusted within 24 hours.

Hints:

After replacing batteries or a power failure happens, time

setting should be reset.

According to the Time setting sequence of TIMER ON or

TIMER OFF, either Start-Stop or Stop-Start can be achieved. 

 Timer On/Off  On-Off Operation 

 Healthy Airflow Operation

1.Press          to start

Setting for comfortable conditions.

2.The setting of healthy airflow function

Note:

1.After setting the healthy airflow function, the position 

 louver is fixed.

4.In cooling and dry, using the air conditioner for a long 

time under the high air humidity, condensate water may

occur at the grille .

3.To cancel of the healthy airflow function

Notice: Do not direct the horizontal louver by hand. This 

may cause the louver to run incorrectly and not match the

display. If the louver is not running correctly, stop the unit 

for a minute and then restart and adjust remote 
controller.

2.In heating, it is better to select the

3.In cooling, it is better to select the 

mode.

mode.

TIMER OFF-ON

0.5h

0.5h

0.5h

0.5h

Press the button for each time, setting time in the first 

12 hours increased by 0.5 hour every time, after 12 

hours,increased by 1 hour every time.

Press the button for each time, setting time in the first 

12 hours decreased by 0.5 hour every time, after 12 

hours,decreased by 1 hour every time.

After adjusting the time,press          button and confirm

the time the ON or OFF button will not flash any more.

4.Confirm timer setting

5.Cancel timer setting

Press the timer button until the  time display eliminated. 

Press           button to enter additional options,Press this 

button continuously, the louvers location will cycle between 

the following three locations, to choose the swing location 

what you want, then          button to confirm.

Press          button to enter additional options,Press this 

button continuously, the louvers location will cycle between 

the three locations again, then            button to cancel.

Healthy
airflow
upwarder

Healthy
airflow
downwarder

Present
position

4

Содержание 2HUM18HC003

Страница 1: ...tenido 8 9 12 13 Table des matières 15 20 16 19 PARTS AND FUNCTIONS OPERATION MAINTENANCE CAUTIONS TROUBLE SHOOTING 7 MANTENIMIENTO PRECAUCIONES RESOLUCIÓN DE PROBLEMAS PARTES Y FUNCIONES FUNCIONAMIENTO 14 ÉLÉMENTS ET FONCTIONS UTILISATION ENTRETIEN MISES EN GARDE DÉPANNAGE 21 HSU09VHG DB G HSU12VHG DB G HSU18VHG DB G HSU24VHG DB G HSU09VHG DB W HSU12VHG DB W HSU18VHG DB W HSU24VHG DB W HSU109VHG ...

Страница 2: ......

Страница 3: ...remote 22 HOUR button Operation mode N A F O T U A COOL DRY Remote controller HEAT 1 2 3 4 5 9 10 11 12 13 14 15 16 17 22 23 24 25 19 20 21 8 18 7 6 Control the lightening and extinguishing of the indoor LED display board 3 SWING display 8 9 QUIET button 10 HEAT button 11 COOL button 12 AUTO button 13 FAN button 14 TIMER button 15 HEALTH button 17 LIGHT button 18 POWER ON OFF button 19 DRY button ...

Страница 4: ...e the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is disabled In FAN mode sleep operation is not available Emergency Operation Use this operation only when the remote controller is defective or lost and with function of emergency running air conditoner can run automatically in few seconds When power switch is turned on for the ...

Страница 5: ...er SLEEP mode starts temp will become 2 4 F lower than temp setting After another 1 hour temp decrease by 2 C 4 F futher After more another 3 hours temp rises by 1 C 2 F futher The unit will run for an additional 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep If the unit is running cooling the sleep mode will follow the function as in c...

Страница 6: ...ay cause the louver to run incorrectly and not match the display If the louver is not running correctly stop the unit for a minute and then restart and adjust remote controller 2 In heating it is better to select the 3 In cooling it is better to select the mode mode TIMER OFF ON 0 5h 0 5h 0 5h 0 5h Press the button for each time setting time in the first 12 hours increased by 0 5 hour every time a...

Страница 7: ...ong term exposure to sunlight when not in use as its ability to sterilize will be reduced For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter faces outside and the black side faces the unit The green side of the bacteria killing medium air purifying filter faces outside and the white side faces the unit Do not use water ...

Страница 8: ...ed service technician Do not place or store any objects on the indoor unit CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplace or other heating apparatus Install the outdoor unit securel...

Страница 9: ... flow in unit operation air be heard At first 2 3 minutes after unit start this noise is more noticeable will work for 3 minutes to protect the air conditioner immediately until 3 minutes have Cautions Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on ...

Страница 10: ...potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or Repair the product or products dealt with in this service information by anyone else could result in serious injury or death WARNING 2013 Qingdao Haier Air Conditioner General corp Ltd All rights reserved Unauthor...

Страница 11: ...Removal of procedure 1 Removal of Air Filter 1 Domestic Air Condition ...

Страница 12: ...val of procedure 2 Please embed the two during installation hooks on air filter completely into the unit Please embed the air filters into the unit along the grooves as installation 2 Domestic Air Condition ...

Страница 13: ...start the removal procedure of front grille one side to another to release each axis until it is on the horizontal position and then release the pivots on both sides of the unit to remove the front panel 2 Removal of front panel 3 Domestic Air Condition ...

Страница 14: ...Removal of procedure three two HOOKS 4 Domestic Air Condition ...

Страница 15: ...Removal of procedure 3 Removal of horizontal flap flap flap flap flap 5 Domestic Air Condition ...

Страница 16: ...Removal of procedure 4 Removal of Drain pan 6 Domestic Air Condition ...

Страница 17: ...Removal of procedure 5 Removal of vertical blades and swing motor 7 Domestic Air Condition ...

Страница 18: ...Removal of procedure 6 Removal of Electrical Box 8 Domestic Air Condition ...

Страница 19: ...Removal of procedure 7 Removal of Heat Exchanger 9 Domestic Air Condition ...

Страница 20: ...Removal of procedure 10 Domestic Air Condition ...

Страница 21: ...Removal of procedure 8 Removal of Fan Rotor and Motor 11 Domestic Air Condition ...

Страница 22: ...Removal of procedure 12 Domestic Air Condition ...

Отзывы: