ERROR CODES & PROBLEM SOLVING
PAGE 56
ENGLISH
Red
Orange
Yellow
Pink
Blue
Grey
Red
193.0 Ohm 189.5 Ohm 185.4 Ohm
191.5 Ohm
---
Orange
381.6 Ohm 377.4 Ohm
383.3 Ohm 47.0 Ohm
Yellow
373.9 Ohm
379.9 Ohm
---
Pink
375.8 Ohm
46.8 Ohm
Blue
---
Grey
Step 3
Re-seat the plug on the connector at the conclusion of the
test.
Checking the Indoor DC Fan Motor
Step 1
Disconnect the DC Fan Motor plug from the control board
connector for this test. Failure to do so may provide
inaccurate readings.
Step 2
Refer to the chart shown below for plug pin combinations and
resistance values.
Note: Test is polarity sensitive, adhere to probe placement as
shown in chart.
Red Test Lead
Black
Test
Lead
Pink
X
X
Black
White
Blue
Yellow
Pink
X
X
15.27Meg 15.46 Meg
Infinity
15.85 Meg
X
X
X
X
X
X
X
X
X
X
X
Black
108.2K
Infinity
241.8K
White
Infinity
349.5K
Blue
5.14 Meg
Yellow
Step 3
Re-seat the plug on the connector at the conclusion of the
test.
Содержание 1U09ES2VHA
Страница 2: ... This page intentionally left blank ...
Страница 6: ...INTRODUCTION PAGE 6 ENGLISH This page intentionally left blank ...
Страница 18: ...REMOTE CONTROL FUNCTIONS PAGE 18 ENGLISH This page intentionally left blank ...
Страница 34: ...SEQUENCE OF OPERATION PAGE 34 ENGLISH This page intentionally left blank ...
Страница 44: ...INSTALLATION PAGE 44 ENGLISH This page intentionally left blank This page intentionally left blank ...
Страница 58: ...REFERENCE INFORMATION PAGE 58 ENGLISH Outdoor Board Diagram ...
Страница 61: ...REFERENCE INFORMATION PAGE 61 ENGLISH Indoor Board Diagram ...
Страница 75: ... This page intentionally left blank ...