INDOOR UNIT CONTROLS & COMPONENTS
PAGE 17
ENGLISH
Stepper Motor Louver
Fan Motor
Emergency Button
The Indoor Fan Motor is a variable speed motor. The
motor will vary speed with the speed of the compressor
inverter. The speed can also be set at the remote control
or automatically adjusted using the AUTO fan mode. When
in AUTO fan mode, the speed of the fan is calculated using
the indoor set temperature and the indoor room ambient
temperature. (Outdoor air temperature in heat mode.)
The Fan Motor is connected to the indoor control board via
PLUG CN-9.
If the remote control is non-functional, the Emergency
Button can be accessed by swinging open the front of the wall
unit. The button is located on the right side.
Pushing this button will activate AUTO MODE operation.
AUTO MODE activated with this button will maintain 75°F.
The system will stay in this mode until commands are
received by the indoor unit communication circuit via the
remote control.
The STEPPER MOTOR moves the louver up or down, and
right or left depending upon selections made at the remote
control.
The motor is connected to the indoor control board at PLUG
CN-11.
Содержание 1U09ES2VHA
Страница 2: ... This page intentionally left blank ...
Страница 6: ...INTRODUCTION PAGE 6 ENGLISH This page intentionally left blank ...
Страница 18: ...REMOTE CONTROL FUNCTIONS PAGE 18 ENGLISH This page intentionally left blank ...
Страница 34: ...SEQUENCE OF OPERATION PAGE 34 ENGLISH This page intentionally left blank ...
Страница 44: ...INSTALLATION PAGE 44 ENGLISH This page intentionally left blank This page intentionally left blank ...
Страница 58: ...REFERENCE INFORMATION PAGE 58 ENGLISH Outdoor Board Diagram ...
Страница 61: ...REFERENCE INFORMATION PAGE 61 ENGLISH Indoor Board Diagram ...
Страница 75: ... This page intentionally left blank ...