background image

42

43

For All Models:

Use clean white pellet, cube-style, or solar salt. 

Drain Line (Minimum I.D.) 1/2-inch (1.3 cm)

Height–inches (cm) 38–1/4 (97)

Salt storage capacity–lb (kg) 200 (90)

Electrical rating: 115V, 60 cycle

Valve Inlet/Outlet–1 inch

Water Temperature (Min-Max) 40°–120°F (4°–49°C)

Floor Space–inches (cm) 15 x 30 (38 x 76)

Brine & Rinse total–gpm (L/min) 0.75 (2.5) 

Brine Draw–gpm (L/min) 0.25 (0.9)

Rinse–gpm (L/min) 0.5 (1.5) 

Iron reduction to 0.3 ppm or less (Not certified by WQA.)

*Listed with the U.S. EPA as a Bacteriostatic Device U.S. EPA # 54369-

OH-001. Not certified by WQA

2AMQ

1

2APQ

1

2AKQ

2AJQ

3

Max Compensated Hardness–gpg (g/L)

90 (1.5)

90 (1.5)

90 (1.5)

60 (1.0)

Iron (ppm)

1

 ferrous-clear water 

Maximum ferrous iron reduction

2

12

5

2-12

5,7

15

5

Minimum pH–standard units

7

7

7

6.3

Tannin–ppm

0

0

0

0

Sulfur–ppm-SulfurStat

0

0-5

7

0

0

Maximum Chlorine–ppm

0

0

0

0

Filtration-nominal rating-microns

20

20

20

20

Media Amount Compartment #1

8

–lb (kg)

Empty

Empty

Empty

Empty

Media Amount Compartment #2

8

–cu. ft. (L)

6 lb 

(2.7 kg)

27 lb 

(122.2 kg)

0.4 (11.3)

0.4 (11.3)

Media Amount Compartment #3 Fine Mesh Cation Resin–cu. ft. (L)

1.06 (30)

1.06 (30)

1.06 (30)

1.06 (30)

Backwash Rate @ min. water pressure  

maximum flow to drain–gpm (L/min)

2.4

4

 (9.1)

3

9

 (11.4)

3

9

 (11.4)

2.4

4

 (9.1)

Brine Line Flow Control Refill–gpm (L/min)

0.5 (1.9)

0.5 (1.9)

0.5 (1.9)

0.5 (1.9)

Water Pressure–min–max psi (bar)

20–80

(1.4–5.5)

30–80

(1.4–5.5)

30–80

(1.4–5.5)

30–80

(1.4–5.5)

Flow Rate @ 15 psi (1.0 bar) drop-as tested  

–gpm (L/min)11

12.2 (46.2)

12.7 (48.1)

10.6 (40.1)

12.5 (47.3)

Pressure Drop in psi (bar) @ Service Flow Rate  

of 8 gpm (30.3 L/min)

7.8 (0.5)

6.0 (0.4)

10 (0.7)

11 (0.8)

#1 Setting–Salt lb/grains (kg/grams) removed

1.1/5,700

(0.5/369)

NA

NA

NA

#2 Setting—Salt lb/grains (kg/grams) removed

2.7/12,000

(1.2/778)

NA

NA

2.7/11,900

(1.2/771)

#3 Setting—Salt lb/grains (kg/grams) removed

6.2/23,400

(2.8/1,520)

6.2/24,600 

(2.8/1,594)

6.2/23,100 

(2.8/1,500)

6.2/23,100 

(2.8/1,500)

#4 Setting—Salt lb/grains (kg/grams) removed

9.3/30,600

(4.2/1,980)

9.3/32,100 

(4.2/2,080)

9.3/30,300 

(4.2/1,960)

9.3/30,300 

(4.2/1,960)

#1 Salt Setting–Total length of reg. Min/gal (L)

25/31

(25/117)

NA

NA

NA

#2 Salt Setting–Total length of reg. Min/gal (L)

28/32

(28/121)

NA

NA

34/70

(34/265)

#3 Salt Setting–Total length of reg. Min/gal (L)

31/35

(31/132)

37/78

(37/295)

37/78

(37/295)

37/78

(37/295)

#4 Salt Setting–Total length of reg. Min/gal (L)

36/37

(36/140)

41/80

(41/303)

41/80

(41/303)

41/80

(41/303)

Shipping weight–lb (kg)

140 (64)

167 (76)

160 (73)

180 (82)

Bacteriostatic-KDF® Process Media*

Yes

Yes

Yes

Yes

1

 Models 3MAQ, 3BAQ, 3BEQ, 2MXQ, 2AMQ and 2APQ are certified by WQA for barium and radium reduction 

as verified and substantiated by test data. All other models are not certified by WQA and make no health 

claims.

2

 Municipally supplied chlorinated water only.

3

 Calcite will add additional hardness to water before softening. 

4

 Any hardness over 10 gpg (0.17 grams/liter) will increase the chance of calcium carbonate precipitation. As the

  hardness increases so does the chance of this precipitation. Must use citric acid to regenerate along with salt. 

5

 Regeneration every 96 hours is required when iron is present in the raw water supply unless noted otherwise.

  Use Salt Setting #3 or #4. 

6

 Iron reduction claims limited to 5 ppm in the state of Wisconsin.

7

 Must have a minimum of 2 ppm iron and a minimum of 200 ppm TDS. 

8

 When adding media in the field, check for proper settings. (See Water Conditioner Specifications, above.) 

9

 Rate of flow must be verified at the end of 1/2-inch I.D. drain line. 

10

 This model has no backwash flow control button or retainer. Must have a minimum of 7 gpm @ 30 psi 

 

 (26.5 L/  min @ 2.1 bar) available for proper backwash. 

11

 For the purposes of plumbing appliance sizing, only the rated service flow rate and corresponding pressure 

loss may be used. Prolonged operation of a water softener at flow rates exceeding the tested service flow rate 

of 8 gpm (30.3 L/min) may compromise performance.

Name of Substance

USEPA Max.Contaminant Level

pH

Flow Rate

Pressure

Barium

2.0 mg/l

7.5 ± 0.5

10.0 gpm (37.9 L/min)

35 ± 5 psig (2.4 ± 0.3 bar)

Radium 226/228

5 pCi/L

7.5 ± 0.5

10.0 gpm (37.9 L/min)

35 ± 5 psig (2.4 ± 0.3 bar)

Reduction capabilities for specific contaminants verified by test data.

Filter

Purpose

1AAN

Reduces iron, iron algae, and bacteria. Reduces manganese. Also reduces up to 5 ppm 

Hydrogen Sulfide with the presence of 2 ppm iron. For regeneration frequency, see 

1AAN 

WaterMax

®

 Filter Sizing Formula

 for this model.

1AAE-BWO

Reduces tastes, odors and will reduce most man-made pollutants. Backwash every 3 days or as

needed. 

Warning:

 Must not be backwashed for 24 hours after installation.

1AAR-BWO

Reduces suspended matter (turbidity) from water down to the 20–40 micron range. Backwash 

every 3 days or as needed

1AAS-BWO

Will raise the pH of most low pH water. The mineral media must be replenished periodically to

maintain optimum bed depth for effective correction. Backwash every 2 days to prevent 

solidification of mineral media.

1AAF-BWO

Reduces suspended matter (turbidity) from water down to nominal 20 microns. Backwash every

3 days or as needed.

Filter

1AAN

1AAE-BWO

1AAR-BWO

1AAS-BWO

1AAF-BWO

Capacity-ppm

10,000

N/A

N/A

N/A

N/A

Sulfure H

2

S

5

N/A

N/A

N/A

N/A

Iron-ppm

20

N/A

N/A

N/A

N/A

Minimum pH

7

N/A

N/A

5

1

N/A

Media type

Manganese 

Greensand (N)

Activated Carbon (E)

Filter Ag (R)

Calcite/Corosex (S)

Multi-Grade (F)

Media amount-cu. ft. (L)

1.25 (35.4)

1 (28.3)

1.25 (35.4)

1.25 (35.4) 

1 (28.3)

Cont. flow rate-gpm (L/min)

6 (23)

6 (23)

6 (23)

6 (23)

6 (23)

Peak flow rate-gpm (L/min)

10 (38)

10 (38)

10 (38)

10 (38)

12 (45)

Backwash rate-gpm (L/min)

7 (26)

5 (19) 

5 (19) 

7 (26)

7 (26)

Brine line flow control-gpm (L/Min)

0.5 (1.9)

N/A

N/A

N/A

N/A

Water Pressure-psi (bar)

30–80 (1.4–5.5)

30–80 (1.4–5.5)

30–80 (1.4–5.5)

30–80 (1.4–5.5)

30–80 (1.4–5.5)

Mode settings

1

1

1

1

1

Backwash #1-min

5

7

7

7

7

Brine/rinse-min

45

0

0

0

0

Backwash #2-min

3

0

0

0

0

Salt (lb) 3 lb salt setting=4 oz (118g) 

KMnO

4

2

3

0

0

0

0

Regenerant used

4 oz (118g) KMnO

4

2

N/A

N/A

N/A

N/A

Flow rate at 25 psi (a.7 bar) drop-gpm 

(L/min)

16.7 (63.2)

21.4 (81.0)

21.5 (81.4)

20.4 (77.2)

19.4 (73.4)

Flow rate at 15 psi (1.0 bar) drop-gpm 

(L/min)

10.5 (39.7)

15.9 (60.2)

15.9 (60.2)

15.2 (57.5)

15.2 (57.5)

Service flow in gpm (L/min) @ pressure 

drop

3

 in psi (bar)

[email protected] 

([email protected])

[email protected] 

([email protected])

[email protected] 

([email protected])

[email protected] 

([email protected])

[email protected] 

([email protected])

The following table describes the available filters. 

Refer to the following specifications for the 

WaterMax

®  

water filtration appliances Signature Series

1

 The 1AAS-BWO will raise the pH of most, but not all low pH water. Some water requires chemical injection using a chemical feed pump.  

2

 

Caution:

 Follow the instructions on the KMnO4 container.  

3

 For optimum water quality, do not exceed recommended service flow rate for filter media type

Specifications

Specifications

Содержание WATERMAX SIGNATURE Series

Страница 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Страница 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Страница 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Страница 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Страница 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Страница 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Страница 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Страница 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Страница 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Страница 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Страница 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Страница 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Страница 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Страница 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Страница 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Страница 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Страница 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Страница 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Страница 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Страница 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Страница 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Страница 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Страница 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...