Customer Settings, cont.
Set Number of People
Display reads “# People” followed by the current setting for the number of people in the household (Ex. 4).
To Change the Number of People
A.
Enter the number of people in the household.
B.
When the desired number of people is displayed, press Ok.
Note:
Whenever you experience an electrical outage, check your controller for the correct time and day. Make any necessary
corrections.
Step 6
Salt Depths
Based on the water level measured from the bottom of the brine cabinet with grid plate, the following depths correlate to the
amount of salt used per regeneration:
Note:
Bold numbers pertain to available settings listed under Mode 1 and 2 Service Settings.
To maintain peak performance of the appliance, inspect and clean the brine tank and air check/draw tube assembly annually
or when sediment is present in the brine tank.
Modes 1 and 3
Mode 2
Salt–lb (kg)
Depth–in. (cm)
Salt–lb (kg)
Depth–in. (cm)
1
1.0 (0.5)
5-3/4 (14.6)
1.0 (0.5)
5 (12.7)
1.6 (0.7)
6 (15.2)
1.6 (0.7)
5-1/4 (13.3)
2.5 (1.1)
7-5/8 (19.4)
2.5 (1.1)
5-7/8 (14.9)
2.7 (1.2)
8 (20.3)
2.7 (1.2)
5-7/8 (14.9)
3.0 (1.4)
8-7/8 (22.6)
3.0 (1.4)
6 (15.2)
4.2 (1.9)
9-5/8 (24.4)
4.2 (1.9)
7-1/4 (18.4)
6.0 (2.7)
11-7/8 (30.2)
6.0 (2.7)
8-7/8 (22.6)
6.2 (2.8)
12 (30.5)
6.2 (2.8)
8-7/8 (22.6)
6.5 (2.9)
12-3/8 (31.4)
6.5 (2.9)
9 (22.9)
8.5 (3.9)
14-3/4 (37.5)
8.5 (3.9)
9-5/8 (24.4)
9.0 (4.1)
15-3/8 (39.1)
9.0 (4.1)
9-7/8 (25.1)
9.3 (4.2)
15-7/8 (40.3)
9.3 (4.2)
10 (25.4)
9.6 (4.4)
16-1/2 (41.9)
9.6 (4.4)
10-3/4 (27.3)
10.7 (4.9)
17-3/8 (44.1)
10.7 (4.9)
11-3/4 (29.8)
14.4 (6.5)
22 (55.9)
14.4 (6.5)
13-5/8 (34.6)
1
These depths reflect 50% of the total brine refill for the Absolute Brining feature.