background image

4

5

General Information

Congratulations

 on choosing a superior Hague water treatment appliance! Soon you and your 

family will be enjoying clean, clear water. Use this guide to attain the maximum benefit from 

your appliance. As an owner, you may find the first few pages to be the most helpful in solving 

your needs. If you have trouble with the operation of your appliance, see 

Troubleshooting

 in the 

back of this manual or contact your independent Hague dealer.

Warning:

 This appliance must be applied to potable water only. It is recommended that an 

independent Hague dealer install and maintain this appliance.

Note:

 The manufacturer reserves the right to make specification and product changes without 

prior notice.

This manual is for installation, operation, and maintenance of the following water conditioning appliance models:

If your specific model is not listed here, your appliance has been customized to solve additional water conditioning problems 

that you may have. Your dealer will be happy to explain any additional special features.

Note:

 For Model 2AJQ, be sure to read 

2AJQ Replenishment Procedure

. For Model 1AAN, be sure to read 1AAN  

WaterMax

®

 

Iron Filter Sizing Formula and Iron Filter and Potassium Permanganate Feeder Installation Guide

.

For Owner’s Reference

Date of Installation:
Model Number:
Serial Number

1:

Installer’s Signature:
Dealership Name:
Dealership Address:

Dealership Phone Number:
Hardness:
Iron:
pH:
Water Pressure:
Water Temp:
Warranty Registration Date

2

:

1

 The serial number is located on the left front support panel.

2  

Visit https://www.haguewater.com/warranty-registration/ to register your Hague product warranty online. 

Getting Maximum Efficiency From the Appliance

To achieve the maximum benefit and performance from 

this appliance, familiarize yourself with this manual and 

the appliance.

1.

  The salt level should always be at least 1/3 full. Refill 

the salt when the level drops below the water level 

in the brine cabinet. A resin cleaner can be used on 

a monthly basis. Clean white pellet, cube-style, or 

solar salt is recommended. Do not use rock salt. 

      Caution:

 Do not mix different types of salt.

2.

  You may use a salt substitute (such as potassium 

chloride) in place of water conditioner salt. A Hague 

dealer should be contacted before a switch is 

made to a salt substitute. If potassium chloride is 

used in place of salt, the technician must select the 

potassium option during the programming of the 

controller. 

See Service Settings

      

Caution:

 Do not use potassium chloride if there is 

iron and/or manganese in the water.

3.

  Should your electricity be off for any reason, check 

your controller for the correct time and reset as 

necessary. See 

Customer Settings

.

4.

  Program the appliance to regenerate at a time 

when the water is not being used. If there is more 

than one appliance, allow two hours between each 

regeneration.

5.

  If dirt, sand, or large particles are present in the 

water supply, the appropriate Hague filter can 

eliminate this problem. See 

Filter Specifications.

6.

  The appliance may be disinfected with 5.25% 

sodium hypochlorite, which is the active ingredient 

in household chlorine bleach. To disinfect the 

appliance, add 4.0 fluid ounces (120 mL) of chlorine 

bleach solution to the brine well of the brine tank. 

The brine tank should have water in it. Start a 

manual regeneration.

7.

  Protect the appliance, including the drain line, from 

freezing.

8.

  The bypass valve (attached to the main control 

valve) enables you to bypass the appliance if 

any work is being performed on the appliance, 

well pump, or plumbing. See 

Bypass Valve

. Use 

Bypass mode also for watering plants or lawns 

with untreated water. To bypass, turn the blue 

knob counterclockwise until it hits the stop; turn it 

clockwise to restore service.

9.

  Before putting the appliance back in service after 

work has been performed, turn on the nearest cold 

water tap until water runs clear.

10.

 Adhere to all operational, maintenance, and 

placement requirements.

11.

  Inspect and clean the brine tank and air check/draw 

tube assembly annually or when sediment is present 

in the brine tank.

12.

 Potassium permanganate will need to be added 

periodically to any iron filter.

13.

 These appliances are certified for barium and radium 

226/228 reduction according to NSF/ANSI Standard 

44. Any bypass system must be completely in the 

Service position to ensure maximum barium and 

radium 226/228 reduction.

 

WaterMax

®

  

3MAQ*

  

 

WaterMax

®

  

3MDQ

  

 

WaterMax

®

  

2AJQ

  

 

WaterMax

®

  

3BAQ*

  

 

WaterMax

®

  

2AMQ*

  

 

WaterMax

®

  

1AAN

 

WaterMax

®

  

3BEQ*

  

 

WaterMax

®

  

2APQ*

  

*

Tested by WQA

 

WaterMax

®

  

2MXQ*

  

 

WaterMax

®

  

2AKQ

 

Содержание WATERMAX SIGNATURE Series

Страница 1: ...Water Conditioning Appliance SIGNATURE SERIES Owner s Manual and Installation Guide Version 1 0...

Страница 2: ...ing these substances in the appliance specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise Hague Quality Water In...

Страница 3: ...s potassium chloride in place of water conditioner salt A Hague dealer should be contacted before a switch is made to a salt substitute If potassium chloride is used in place of salt the technician mu...

Страница 4: ...0 F 4 49 C Drain Drain the appliance to an appropriate drain such as a floor drain or washer drain that will comply with all local and state plumbing codes To prevent back siphoning provide an adequat...

Страница 5: ...should make the shortest run to the suitable drain C The drain line may be elevated up to 8 feet 2 4 meters from the discharge on the appliance as long as the water pressure in your system is 40 psi...

Страница 6: ...old water faucet to depressurize the lines 3 Close the faucet to eliminate any siphoning action 4 Repair all leaks 5 Turn on the water supply 6 Place the bypass in the Service position to slowly fill...

Страница 7: ...jectionable concentrations of ferrous iron or sediment are present Because the blending valve is mixing raw water with softened any ferrous iron or sediment in the raw water will also be blended and r...

Страница 8: ...ce Settings History No Total Regenerations Displays the number of regenerations since the last time Service Settings mode was entered Value resets to 0 once the number is viewed 0 Total Gallons Displa...

Страница 9: ...m 30 psi available for proper backwash 5 Calcite will add additional hardness to water before softening 6 If iron is present in water supply use salt setting 3 or 4 7 If iron is present in the water s...

Страница 10: ...tings Mode 3 is NOT recommended for residential use ST Series 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ3 2AMQ1 2APQ1 3 4 2AKQ3 2AJQ3 5 Mode 1 Yes Yes Yes Yes No Yes No No No Regeneration Frequency As Required...

Страница 11: ...ttings To maintain peak performance of the appliance inspect and clean the brine tank and air check draw tube assembly annually or when sediment is present in the brine tank Modes 1 and 3 Mode 2 Salt...

Страница 12: ...C Close the tap Remove Water From Media Tank A Remove the fill plug from the media tank using a 3 4 inch socket B Insert the siphon hose into the fill port C Siphon the water into the bucket down to...

Страница 13: ...L x 3 ___ ppm mg L 0 2 ppm mg L x 3 0 6 ppm mg L Sulfur ___ ppm mg L x 5 ___ ppm mg L 1 0 ppm mg L x 5 5 0 ppm mg L Total compensated ppm ___ ppm mg L 9 1 ppm mg L x Gallons per day for one person 75...

Страница 14: ...the container when working with potassium permanganate Use care when removing the cover and pouring it into the feeder B Place the cover on the feeder and secure it with the three stainless steel scr...

Страница 15: ...4 3 100241828 Drain End Cap and Container No DLFC See Figure 17 1 4 100241865 O Ring 2 5 100242049 Sleeve 2 6 100241807 Fill Plug 1 7 100241870 O Ring 1 8 100242050 O Ring 2 9 100241175 Bypass Valve...

Страница 16: ...t draws the brine solution from the Brine Cabinet The small hole in the Injector Nozzle is the one that creates the injection stream that enters the Throat It is important that this hole is round unda...

Страница 17: ...the Sensor Housing The cap is then put in place and the self tapping mount ing screw is installed A slot is provided in the cap for the wire to exit The three wire socket connector must be properly in...

Страница 18: ...ft that runs through the main drive axle The Drive Gear is attached at the short end and the Magnet Disc at the other end The Slide Cam is assembled inside of the Piston Slide This Cam Shaft should tu...

Страница 19: ...e and then using a twisting action insert the Salt Monitor Probe into the housing Monitor Probe into the housing Caution Caution The 3 8 inch locking clip must be installed to prevent air from being d...

Страница 20: ...r No electric power at outlet Check power source Make sure outlet is not controlled by a switch Defective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14...

Страница 21: ...egenerant potassium permanganate 3MAQ1 3BAQ1 2 3BEQ1 2 2MXQ1 3MDQ Max Compensated Hardness gpg g L 90 1 5 90 1 5 90 1 5 110 1 9 904 1 5 Iron ppm 1 ferrous clear water Maximum ferrous iron reduction2 0...

Страница 22: ...minimum of 200 ppm TDS 8 When adding media in the field check for proper settings See Water Conditioner Specifications above 9 Rate of flow must be verified at the end of 1 2 inch I D drain line 10 T...

Страница 23: ...2022 A O Smith All Rights Reserved 100359102 DOCUMENT NUMBER RevA0123 A O Smith Water Treatment North America Inc...