Installation Steps and Start-Up Procedures, Cont.
Step 8
Check for Leaks
A.
Close all faucets.
B.
Check all lines and connections for leaks. If leaks are found:
1.
Turn off the main water supply.
2.
Open a cold water faucet to depressurize the lines.
3.
Close the faucet to eliminate any siphoning action.
4.
Repair all leaks.
5.
Turn on the water supply.
6.
Place the bypass valve in the Service position to slowly fill the media tank.
7.
Open a cold water faucet to purge air out of the media tank.
8.
Close the faucet and recheck for leaks.
Step 9
Plug in the Transformer
A.
Connect the transformer power cord to the back of the controller.
B.
Plug the transformer into an appropriate outlet.
C.
Ensure that the outlet selected is not operated by an On/Off switch.
Step 10
Set Up the Controller
A.
Program the appliance controller. See
Setting and Using the Controller
.
Step 11
Add Water to the Brine Tank
A.
Add water to the brine tank to a minimum of 2 inches (5 cm) above the grid plate. After the
first regeneration, the appliance will automatically refill the correct amount of water into the
brine tank.
B.
Ensure that the bypass valve is in the Service position.
C.
Ensure that the salt dosage is set as recommended for the application.
D.
Initiate a manual regeneration (see
Setting and Using the Controller
) and inspect for proper
operation. Allow the appliance to draw all the water out of the brine tank until the air
check/draw tube sets (8–10 minutes).
E.
Press the Regenerate button to advance to the Brine Refill position. Let the tank fill with the
proper amount of water. The controller will then step the main control valve to the Home
position.
Note:
This initial startup is the only time you will add water to the brine tank. Do not add
water at any other time.
Step 12
Fill the Brine Tank With Salt
A.
Fill the brine tank with salt. Use clean white pellet, cube-style, or solar salt. Do not mix pellet
with solar salt.
Note:
Always keep the salt level above the water level. For convenience, completely fill the
tank when refilling with salt.
B.
After you add salt, including adding it after the tank has run out of salt, wait two hours for
saturated brine before starting any regeneration.
Caution:
Use of potassium chloride when iron and/or manganese are present in the raw
water supply is not recommended.
Содержание Hydroclean HC3