TE331
9
6T 8722-02a
Possible installations are given below for the configuration of the electricity metering channels only.
* Inputs x, y and z can be allocated to Sockets or Others use to possibly benefit from additional sub-metering:
-
Possible values for Sockets: different socket circuits
-
Possible values for Others: different lighting, pump or CMV circuits
■
Example 1: Electric heating and electric DHW or heat pump + DHW boiler
Channel settings:
Channel x: Heating
Channel y: DHW
Channel z: Sockets
Others = TIC* - (H DHW + Sockets)
* Client Tele-Information
2.3 Possible installations
Installation type
Input x
Input y
Input z
Additional settings
Electrical h DHW
boiler
OR
Heat pump + DHW boiler
Heating
DHW
Sockets
/
2 in 1 heat pump (H
DHW)
Heating / DHW
Not used or sockets
or others*
Sockets
Heating / cooling dates (See
settings)
3 in 1 heat pump (H
C DHW)
Heating / Cooling /
DHW
Not used or sockets
or others*
Sockets
Heating / cooling dates (See
settings)
DHW distribution key (Installer
settings)
Reversible heat pump with
separate DHW production
Heating / Cooling
DHW
Sockets
Heating / cooling dates (See
settings)
Heating and DHW production
other than electrical
Not used or sockets
or others*
Not used or sockets
or others*
Not used or sockets
or others*
/
Others
Sockets
DHW Heating