TE331
11
6T 8722-02a
■
Energy saving function
■
Energy management function
Note:
Group addresses are automatically allocated for:
•
The
Power, Total energy, Partial energy, Dynamic mode
and
Reset
objects for the Metering function (Valid for the 7
channels),
•
The
Current tariff
and
Coming tariff
for the Tariff function.
Group addresses
are not
automatically allocated for:
•
The
Tariff
object for the Metering function (Valid for the 4 channels),
•
The
Ext. temp
object for the Temperature function.
The information concerning these objects may come from the device or the bus.
3. TE331 inputs and outputs
Inputs
Numbering
Outputs
1 temperature channel
+info
Inputs
Numbering
Outputs
7 metering channels (3 strength of current transformers
+ the tele-info link + ad other + three-phase)
1 tariff information channel
+info
4. Product installation
Steps to follow
Actions on TX100
Programming the product
Press the
key to start memorisation.
Automatic allocation of group addresses
•
Go to Menu / Installation management / domovea,
•
Confirm "Addition" in domovea,
•
Wait for downloading to complete.
Rem: Only version 2.7.58 of TX100 and higher.
Manual allocation of group addresses for the
Metering
object
tariff
Activate expert mode for display
•
Go to Menu / Expert / Standard,
•
Activate the Expert mode,
•
Go to Programming Mode,
•
Select the metering channel,
•
Go to expert mode to display the objects,
•
Go to Tariff,
•
Click on Addition,
•
Enter the group address and confirm.
Optional step:
Display of the group addresses
•
Go to Programming Mode,
•
Go to expert mode to recover the group addresses.
Saving the project on a USB key to recover the group
addresses on domovea
•
Go to Menu / Project management / Backup,
•
Inser the USB key,
•
Select the name of the file and launch backup.
Rem: see chapter 9.2 for programming under demovea.