12
5.52.693.00.01.00
9.2.2
Control line connection
Any changes of the power supply cable must only be effected by qualified personnel.
10
Safety check
Before putting into service initially or when putting back into service, it must be checked whether:
All fastening screws (if existent), socket pins, flap socket and safety devices are tightened and secured.
The oil levels in the gear boxes are sufficient.
All movements of the load comply with the symbols on the control switch.
11
Functional test
11.1
Checks before the initial start-up
Trolley drive
The open-lying teeth of the trolley drive must be lubricated.
Hand gear for hand geared trolley
Ensure correct fit of the hand chain; it must not be twisted and must hang freely.
11.2
Functional test
Trolleys
Carefully move the trolley to the end positions and check the positions of the end stops.
12
Maintenance
12.1
General
All monitoring, servicing and maintenance operations are to ensure correct functioning of the equipment;
they must be effected with utmost care.
Only
“qualified persons” may do this work.
Servicing and maintenance work must only be done when the hoist is not loaded.
Records must be kept of all test results and measures taken.
12.2
Monitoring
The monitoring and servicing intervals stated are valid for operation under normal conditions and single-shift
operation. In case of severe operating conditions (e.g. frequent operation with full load) or special
environmental conditions (e.g., heat, dust, etc.), the intervals must be shortened correspondingly
12.3
Brake motor
Electric driven trolleys from 15t are equipped with a brake motor
Connection voltage for the brake 400 VAC
Coil voltage: 180 VDC
trolley
Capacity
t
Brake
type
Nominal brake
moment
Nm
Nominal air gap
mm
air gap
max.
mm
friction lining thick-
ness
min.
mm
15-50
BFK 06
4
0,2
0,5
1,5