PowerSmoke 740 (HV) Operating Instructions
Version 2.0
Our connection set includes all parts in order to allow for optimal flow
rates.
On the pressure side we recommend 2.5mm plastic hoses (PUN) or
Tygon hoses, at least near the exhaust system. We recommend
changing from the plastic or Tygon hose to a heat resistant Viton hose
(close to the muffler) at late as possible (see chapter 6).
Dependant on pressure hose length, injection form, flow rate and
counter pressure a pressure of up to 4 bar can arise in the flow hose.
The pressure hose must support this pressure. In order to connect the
plastic hoses it is advantageous to put some oil onto the connectors or
heating up the hoses carefully. After the hoses are connected, they will
not fall lose themselves anymore. If it is necessary to remove hoses,
they must be cut lose by a side cutter, the same technique is to be
used for removing remaining pieces. Do not use a knife, the
connectors get "scratched" and are possibly not 100% leak proof
anymore. Make sure, no plastic parts enter the pump.
6. Connecting to Exhaust System
A heat resistant hose (available in our shop) is to be put onto the metal
nipple of the muffler or manifold.
Please do not use a plastic or
Tygon hose!
For turbines, the last piece must be of metal material
(stainless steel-, Titan- or brass pipes,
but no aluminum pipe
). We
recommend switching to plastic or Tygon hoses in appropriate distance
to all heat sources.
If a pipe of 3mm outer diameter is used, the hose can be directly put on
(secure with a small bracket or wire). You find fitting hose adapters for
4mm outer diameters in our shop. Also adapters for 3mm Tygon hoses
are available as accessories.
Page 15 of 27