Page 44 of 62
Brushless DC Controller HST-350
Orginal
operating
manual
Rev1.3
Mounting and commissioning
Without relay
Connection without relay is possible. You will need a suitable cable set for this.
DANGER
The system without relay may only be carried out with batteries suitable for this pur-
pose. The system without relay must never be connected to a power supply unit,
regenerated current can destroy this and cause life-threatening damage.
Example (blue lines represent special wiring harness for application without relay):
Motor
L1
L2
L3
Controller HST
-350
35 pin connector
CAN- Adapter
PC
Suitable battery 32,0 - 58,8 V
DC
-
L2
L1
L3
+
Dual CAN
V5-Display
Poti
Kl. 15
Sensor cable (optional)