Habasit Italiana S.p.A.
Vittorio Veneto 31029 (TV)
Tel.: ++39(0)438.9113
Regulating Unit PMR-06
Fax. ++39(0)438.200545
Author:
S.D.T. / KM
SCREEN PAGES MENU
Editon: 12/2005
Page
E-36
Replaces: 05/2005
E.2
PARAMETER TABLES
The working parameters and their corresponding data are listed.
T
ABLE
8
-
L
IMITS AND TOLERANCES
LIMITS and TOLERANCES [°C]
Code ID
Default
Adjustment
field
Unit of
measurement
[Resolution]
Display
mode
Parameter type and description
UP1 200
from
100
to
230
°C [1]
0
Maximum Temperature Set-Point limit for
upper plate
dn1 60
from
Spr+10 to
100
°C [1]
0
Minimum Temperature Set-Point limit for
upper plate
UP2 200
from
100
to
230
°C [1]
0
Maximum Temperature Set-Point limit for
lower plate
dn2 60
from
Spr+10
to
100
°C [1]
0
Minimum Temperature Set-Point limit for
lower plate
SPR 50
from
20
to
70
0
Set-point cooling temperature to stop
cooling
SIC 10
from
10
to
90
% UP1/UP2 - 1
0
Overheating alarm limit (% of Maximum
Set-Point limit for plates)
Ins 0
from
0
to
2
(1=0.5 °C) – 1
0.00
Insensitivity window (+/- relative to Set-
Point)
Tol. 3
from
0
to
2
°C [1]
0
Tolerance window (+/- with respect to Set-
Point)
dP3 20
from
0
to
40
% Set-SP1 [1]
0
Pressure tolerance window (+/- with
respect to Set-point)
Regulating Unit PMR-06