1
•
GPU-T4 GPU module.
When high-performance fans
and processors with a
TDP ≥
240W are used, the following
hardware options are not
supported:
Over 4TB NVMe drive at
the rear.
GPU-T4 GPU module not
in slot 4, 5, or 6.
When high-performance fans
and processors with a
TDP ≥
240W are used, the following
hardware options are not
supported:
Over 1TB NVMe drive at
the rear.
GPU-T4 GPU module not
in slot 4 or 5.
When standard fans and
processors with a
TDP ≤
165W are used, the following
hardware options are not
supported:
•
Over 2 TB NVMe drive
at the rear.
•
GPU-T4 GPU module.
When standard fans and
processors with a
TDP ≤
165W are used, the following
hardware options are not
supported:
•
Over 1TB NVMe drive
at the rear.
•
GPU-T4 GPU module.
When high-performance fans
and processors with a
TDP ≤
165W are used, GPU-T4
GPU modules are supported
in only slots 1, 4, 5, and 6.
When high-performance fans
and processors with a TDP
of
≤ 165W are used, the
following hardware options
are not supported:
Over 4 TB NVMe drive at
the rear
GPU-T4 GPU module not
in slot 4, 5 or 6.
24LFF+12FF+2S
FF
When standard fans are
used, GPU modules are not
supported.
When standard fans are
used, GPU modules are not
supported.
The following
hardware options are
not supported:
•
Standard fans.
•
NVMe drives and
GPU modules at
the rear.
When high-performance fans
and processors with a TDP
≤
165W are used, GPU-T4
GPU modules are supported
in only slots 1, 4, 5, and 6.
When high-performance fans
and processors with a TDP
≤
165W are used, a GPU-T4
GPU module is supported in
only slot 4.
When high-performance fans
and processors with a TDP
≥
240W, GPU-T4 GPU
modules are supported only
in only slots 4 and 5.
When high-performance fans
and processors with a
TDP ≥
240W, a GPU-T4 GPU
module is supported only in
slot 4.
NOTE:
•
The models of high-performance fan module and standard fan module are FAN-H-4UG5 and
FAN-L-4UG5, respectively. For more information about fan modules, see the fan module user
guide.
•
If a fan fails, the maximum server operating temperate decreases by 5°C (41°F), and the GPUs
get underlocked.
Product recycling
New H3C Technologies Co., Ltd. provides product recycling services for its customers to ensure that
hardware at the end of its life is recycled. Vendors with product recycling qualification are contracted
to New H3C to process the recycled hardware in an environmentally responsible way.