6-44
4.
Remove the chassis air baffle. For more information, see "
5.
Install a DIMM:
a.
Identify the location of the DIMM slot.
Figure 6-62 DIMM slots numbering
b.
Open the DIMM slot latches.
c.
Align the notch on the DIMM with the connector key in the DIMM slot and press the DIMM
into the socket until the latches lock the DIMM in place, as shown in
To avoid damage to the DIMM, do not force the DIMM into the socket when you encounter
resistance. Instead, re-align the notch with the connector key, and then re-insert the DIMM.
Figure 6-63 Installing a DIMM
6.
Install the chassis air baffle. For more information, see "
7.
Install the access panel. For more information, see "
."
8.
Rack-mount the server. For more information, see "
9.
Connect the power cord. For more information, see "
10.
Power on the server. For more information, see "