3-5
Figure 3-5
Ethernet cable assembly
When preparing network cables, it is recommended to use shielded cables for the sake of
electromagnetic compatibility.
Connecting the Ethernet cable
Take the fixed 10/100M interface Ethernet 0/0 on the front panel of the V100-E for example. Follow
these steps to connect its Ethernet cable:
Read the symbol above the interface carefully to avoid misconnection.
Step1
Connect one end of the Ethernet cable to the V100-E and the other end to the peer device.
Step2
Check that the LINK LED corresponding to Ethernet 0/0 is on. ON means a link is present on the
interface. OFF means no link is present on the interface and you should check the connection.
Connecting the Power Cable
The V100-E supports dual AC power supplies.
Two AC power modules can serve as backup of each other to implement power redundancy.
AC power supply
AC input: 100 VAC to 240 VAC, 50 Hz or 60 Hz