Operation Manual – QinQ-BPDU Tunneling
H3C S3610&S5510 Series Ethernet Switches
Chapter 2 BPDU Tunneling Configuration
2-7
Note:
When STP works stably on the customer network, if Customer A acts as the root bridge,
the ports of Customer C and Customer D connected with Provider C can receive
BPDUs from Customer A. Since BPDU isolation is enabled on Customer B, the port
that connects Customer B to Provider B cannot receive BPDUs from Customer A.