![H3C H3C S5800-32F Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/h3c/h3c-s5800-32f/h3c-s5800-32f_installation-manual_4183918060.webp)
3-22
Figure 3-35
Connect an AC power cord I
Figure 3-36
Connect an AC power cord II
Connecting a power cord to the PSR750-D (–54 VDC RPS power supply)
To ensure normal PoE power supply to the S5800-60C-PWR using the PSR750-D, you need to select
the RPS1000-A3 of H3C that provides a voltage range from –52V to –55V. Follow these steps to
connect the PSR750-D to the RPS1000-A3:
Step1
Use a Phillips screwdriver to loosen the captive screws and remove the washer of the PSR750-D, as
shown in
Figure 3-37
.
Step2
Insert the captive screws though the washers and OT terminals of the RPS power cords, as shown in
callout 1 in
Figure 3-38
.
Step3
Use the Phillips screwdriver to fix the RPS power cords to the PSR750-D, and ensure a good contact
between the OT terminals and the PSR750-D, as shown in callout 2 in
Figure 3-38
.
Step4
Connect the RPS connectors of the RPS power cords to the outputs OUTPUT1 and OUTPUT2
respectively, as shown in callout 3 in
Figure 3-38
.
Step5
Use a flat-head screwdriver to fix the RPS connectors to the RPS1000-A3.