INSTALLATION
Rules to follow:
• Put the machine on the floor (maximum incline of 10°.)
• Ensure the work area has sufficient ventilation for welding, and that there is easy access to the control panel.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
• The machine must not be used in an area with metal dusts.
• The machine protection level is IP23, which means :
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against the rain inclined at 60% towards the vertical.
These devices can be used outside in accordance with the IP23 protection index.
• Do not use the machine when the temperature is > 40°C.
• The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect
and/or dangerous use of the machine.
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person.
• Ensure the machine is switched off by unplugging it, and then wait 2 minutes before carrying out maintenance work. High
Voltage and Currents inside the machine.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified
person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person to prevent danger.
• Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
• Do not use these machines to unfreeze pipes.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During set up, the operator must
ensure that the machine is unplugged.
HARDWARE DESCRIPTION (FIG-1)
The Exagon 400 CC-CV is a three phase inverter welder which, depending on its equipment, can do :
- Electrode welding (MMA)
- Semi automatic welding (MIG/MAG/flux cored wire)
- Tungsten electrode welding (TIG)
- Carbon electrode gouging
The TIG process requires gas shielding (Argon).
The MMA process can weld any type of electrode : rutile, basic, cellulosic, stainless and brass.
The 400 CC-CV can be equipped with a remote control or foot pedal.
1-
Man to Machine Interface
5-
Wire feeder control cable connector
2-
+ polarity plug
6-
Transport handles and lifting rings
3-
- polarity plug
7-
On/off switch
4-
Remote control cable connector
8-
Power supply cable
CONTROL BOARD (MMI) (FIG-2)
1-
Voltage display
13-
Remote control activation button
2-
Active risk reduction system indicator (VRD)
14-
Active remote control indicator
3-
Current display
15-
Basic electrode indicator
4-
Overheat indicator
16-
Rutile electrode indicator
5-
Disruption of normal operations indicator
17-
Cellulosic electrode indicator
6-
Main setting knob.
18-
MMA mode indicator
7-
Arc-force setting indicator
19-
MMA pulse mode indicator
8-
Variable inductance setting indicator
20-
Voltage mode indicator (CV)
9-
Indicators
21-
Semi-automatic mode indicator
10-
Secondary setting knob
22-
TIG mode indicator
11-
Locked keypad indicator
23-
Gouging mode indicator
12-
Locked keypad button
24-
Selection mode button
Содержание EXAGON 400 CC/CV
Страница 44: ...44 EXAGON 400 CC CV RU 10 40 C 14 104 F 25 55 C 13 131 F 50 40 C 104 F 90 20 C 68 F 2000 6500 10...
Страница 45: ...45 EXAGON 400 CC CV RU 11 2 A CEI 61000 3 11 CEI 61000 3 12 EMF EMF...
Страница 46: ...46 EXAGON 400 CC CV RU a b c d e f g h 10 CISPR 11 2009 a b c d e f...
Страница 54: ...54 EXAGON 400 CC CV RU 40 C 340Veff 460Veff 2...