background image

‘GF’ Series  

Water Softener

INSTALLATION, OPERATION, 

AND MAINTENANCE MANUAL

MODEL NO:

SERIAL NO:

DATE INSTALLED:

DEALER:

COMPLETE FOR FUTURE REFERENCE:

8-569 G&F R2

Содержание GF24

Страница 1: ...GF Series Water Softener INSTALLATION OPERATION AND MAINTENANCE MANUAL MODEL NO SERIAL NO DATE INSTALLED DEALER COMPLETE FOR FUTURE REFERENCE 8 569 G F R2...

Страница 2: ...rine tank cabinet or solu tion container without charge You pay freight one way and local labor charges No allowance is made for consequential damage labor or expense incurred as a result of proven de...

Страница 3: ...tallation Fitting Assemblies 3 Installation Procedures 4 OPERATION Control Valve Function and Cycles of Operation 7 Control Valve Programming 8 Flow Diagrams 12 Bypass Valve Operation 13 MAINTENANCE V...

Страница 4: ...IN OUT INCHES 1 1 1 DRAIN SIZE INCHES 3 4 3 4 3 4 OPERATING PRESSURE MAX PSI 125 125 125 OPERATING TEMPERATURE MAX DEG F 110 110 110 MINERAL TANK SIZE DIA X HT 2 INCHES 8X44 10x47 12x52 BRINE TANK SI...

Страница 5: ...5 ft High Pressure Warning If feedwater pressure is known to be above 100 p s i it is strongly recommended that a pressure reducing valve be installed at this point Hard water to Sprinklers and any d...

Страница 6: ...ape is not necessary on the nut connection or caps because of o ring seals Do not use Vaseline oils or other hydrocarbon lubricants oanywhere on the control valve or resin tank assembly A silicon lubr...

Страница 7: ...valve The bypass valve and the control valve are both marked with arrows that indicate the direction of water flow If water lines are reversed resin maybe forced from the water softener and into hous...

Страница 8: ...13 figure 2 8 Press the REGEN button again to cycle the unit to the next cycle Wait for the piston to stop moving and press the REGEN button again Repeat this until the unit is at the home screen The...

Страница 9: ...ime of day Activate Lockout Feature Press DOWN then NEXT then UP then CLOCK in sequence LOCK will briefly ap pear in the display De activate Lockout Feature Press DOWN then NEXT then UP then CLOCK UNL...

Страница 10: ...g takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut 1 2 above to 1 2 below the top of the tank threa...

Страница 11: ...de using DOWN or UP number of days between regeneration 1 to 28 or OFF See Setting Options Table for more detail on setup Press NEXT to go to step 4I Press REGEN to return to previous step STEP 4I STE...

Страница 12: ...for instructions The fth display will show either DP or HOLD if the dP switch is closed If the system has called for a regeneration that will occur at the pre set time of regeneration the words REGEN...

Страница 13: ...usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a manual regeneration at the preset delayed regeneration tim...

Страница 14: ...ay will ash on and off which indicates the time of day should be reset and the non rechargeable battery replaced The system will remember the rest Error Message If the word ERROR and a number are disp...

Страница 15: ...Y WATER TO TOP OF TANK CONDITIONED WATER FROM DISTRIBUTOR OUTLET PORT FOR SERVICE WATER flow diagram rinse flow diagram fill CONDITIONED WATER TO REGENERANT TANK SUPPLY WATER OUTLET PORT FOR SERVICE W...

Страница 16: ...ndles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this position also allows the control valve...

Страница 17: ...GF SERIESAUTOMATIC WATER CONDITIONERS MAINTENANCE 14 Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly Front Cover and Drive Assembly t t t 14...

Страница 18: ...1 14 A2242054 Transformer 110V 12V 1 Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston and Spacer Stack Assembly Item No Part No Description Quantity 1 A2466034 Spacer Stack Assembly...

Страница 19: ...9 27 28 31 21 Injector Cap Injector Screen Injector Plug O Ring Refill and Refill Port Plug Drain Line 3 4 Proper flow washer orientation directs water flow towards the washer face with rounded edge F...

Страница 20: ...Washer 1 7 gpm for 3 4 A2253081 Drain Flow Washer 2 2 gpm for 3 4 A2253082 Drain Flow Washer 2 7 gpm for 3 4 A2253085 Drain Flow Washer 3 2 gpm for 3 4 A2253086 Drain Flow Washer 4 2 gpm for 3 4 A2253...

Страница 21: ...mplete Specify Model A2042018 2 Brine Tank w Cover A2071005 3 Brine Well A2072003 4 Brine Well Cap A2250003 5 Overflow Elbow A2118010 6 Brine Tube w Air Check B1020001 7 Brine Line Hose w Inserts A200...

Страница 22: ...95069 Nut 1 Quick Connect 1 37 A2360039 Meter Assembly 1 38 A2100027 Turbine Assembly 1 39 use item 51 O Ring 215 Use Valve O ring Kit 1 40 A2287077 Meter Plug Assembly Time clock option 1 Item 37 inc...

Страница 23: ...395009 Bypass Handle 2 47 A2104036 Bypass Rotor Seal Retainer 2 48 use item 52 O Ring 135 use Bypass Valve Kit 2 49 use item 52 O Ring 112 use Bypass Valve Kit 2 50 use item 52 O Ring 214 use Bypass V...

Страница 24: ...n Quantity 1 A2095069 Nut 1 Quick Connect 2 2 A2453012 Split Ring 2 3 A2077178 O Ring 215 2 4 A2569008 Fitting 3 4 1 PVC Solvent 90 2 Order No A2435072 Optional Description Fitting 3 4 Brass Sweat Ass...

Страница 25: ...been ser viced b Foreign matter is lodged in control valve c High drive forces on piston d Control valve piston not in home position e Motor not inserted fully to engage pinion motor wires broken or d...

Страница 26: ...ion b Meter connection disconnected c Restricted stalled meter turbine d Defective meter e Defective PC board f Set up error a Power has been out more than two hours the transformer was unplugged and...

Страница 27: ...GF SERIESAUTOMATIC WATER CONDITIONERS NOTES...

Страница 28: ...8 569 G F R2...

Отзывы: