“GF” SERIES AUTOMATIC WATER CONDITIONERS
INSTALLATION
2
Brine T
ank
Assembly
Softener T
ank
Assembly
Sanitary Drain, Floor Drain or
Laundry T
ubs are acceptable.
Do not make a direct connection
to the drain. An air gap must
be present.
Brine T
ank Overflow drain 1/2”
diameter minimum size
(gravity flow)
Cold hard water inlet
30 p.s.i. minimum pressure
1/2” minimum pipe size
Maximum drain pipe
elevation above drain
port is 5 ft.
High Pressure W
arning:
If feedwater pressure is known to be above
100 p.s.i. it is strongly recommended that a
pressure reducing valve be installed at this point.
Hard water to Sprinklers and any
dersired unsoftened fixtures
Ground Strap
Softened W
ater Outlet
Manual Outlet V
alve
(optional)
Brine Line T
ubing
1
10-125 V
olt
Continuous Power Supply
T
ransformer
Manual Bypass V
alve
(Normally Closed)
(optional)
Manual Inlet V
alve
(optional)
Drain Port
Drain line 1/2” diameter
minimum size
Connection to sanitary sewer line
(optional)
Air gap device
Sanitary sewer line
Drain T
rap
Drain
Typical W
ater Softener Installation