“GF” SERIES AUTOMATIC WATER CONDITIONERS

MAINTENANCE

17

Drawing No. 

Order No. 

Description 

Quantity

 

21 

A2287059 

Refill Port Plug Assembly 

This part is required for backwash only systems

 

22 

A2411015 

Elbow Locking Clip 

1

 

23 

A2409016 

Polytube insert 3/8 

1

 

24 

A2095071 

Nut 3/8 

1

 

25a 

A2080078 

Elbow Cap 3/8                                      (use w/ 3/8” tubing) 

1

 

25b 

A2129100 

Elbow 1/2” with nut and insert               (use w/ 1/2” tubing) 

Option

 

26 

Use Item 51 

O-Ring 019 (Use Valve O-ring Kit) 

1

 

27 

A2104033            RFC Retainer Assembly* 

1

 

28 

A2253108 

RFC Brine Refill Flow Washer 

1

*Assembly includes RFC.

Refill and Refill Port Plug

Drawing No. 

Order No. 

Description 

 

               Quantity

 

29 

A2411015 

Elbow Locking Clip 

 

 

  1

 

30 

A2409013 

Polytube insert 5/8 

 

                Option

 

31 

A2095065 

Nut 3/4 Drain Elbow 

 

                Option

 

32 

A2099056 

Drain Elbow 3/4 Male Assembly 

 

 

  1

 

33 

Use Item 51 

O-Ring 019 (Use Valve O-ring Kit) 

 

 

  1

 

34 

A2104034 

Drain Flow Washer Retainer Assembly 

 

 

  1

 

 

A2253114 

Drain Flow Washer 0.7 gpm for 3/4

 

 

A2253099 

Drain Flow Washer 1.0 gpm for 3/4

 

 

A2253084 

Drain Flow Washer 1.3 gpm for 3/4

 

 

A2253083 

Drain Flow Washer 1.7 gpm for 3/4

 

 

A2253081 

Drain Flow Washer 2.2 gpm for 3/4

 

 

A2253082 

Drain Flow Washer 2.7 gpm for 3/4

 

 

A2253085 

Drain Flow Washer 3.2 gpm for 3/4

 

 

A2253086 

Drain Flow Washer 4.2 gpm for 3/4

 

 

A2253087 

Drain Flow Washer 5.3 gpm for 3/4

35

One

DLFC

must be

used if 3/4

fitting is

used

Drain Line - 3/4”

   Item No. 

Part No. 

Description 

   

           Quantity

 

16 

A2080079 

Injector Cap 

 

 

1

 

17 

Use Item 51 

O-Ring 135 (Use Valve O-ring Kit) 

 

 

1

 

18 

A2142016 

Injector Screen 

 

 

1

 

19 

A2079059 

Injector Assembly Z Plug                                       See note 

 

1

 

 

A2079060 

Injector Assembly A Black 

 

 

A2079048 

Injector Assembly B Brown 

 

 

A2079046 

Injector Assembly C Violet 

 

 

A2079045 

Injector Assembly D Red 

 

20 

A2079049 

Injector Assembly E White 

 

 

A2079047 

Injector Assembly F Blue 

 

 

A2079050 

Injector Assembly G Yellow 

 

 

A2079055 

Injector Assembly H Green 

 

 

A2079062 

Injector Assembly I Orange 

 

 

A2079063 

Injector Assembly J Light Blue

 

                    A2079064                 Injector Assembly K Light Green 

*The injector plug and the injector each contain one 011 (lower) and 013 (upper) o-ring.
  Note:  For downflow brine, injector is located in the down hole and injector plug in the up hole.   

For a filter that only backwashes injector plugs are located in both holes.

1

Injector Cap, Injector Screen, Injector, Plug and O-Ring

t

t

t

Содержание GF24

Страница 1: ...GF Series Water Softener INSTALLATION OPERATION AND MAINTENANCE MANUAL MODEL NO SERIAL NO DATE INSTALLED DEALER COMPLETE FOR FUTURE REFERENCE 8 569 G F R2...

Страница 2: ...rine tank cabinet or solu tion container without charge You pay freight one way and local labor charges No allowance is made for consequential damage labor or expense incurred as a result of proven de...

Страница 3: ...tallation Fitting Assemblies 3 Installation Procedures 4 OPERATION Control Valve Function and Cycles of Operation 7 Control Valve Programming 8 Flow Diagrams 12 Bypass Valve Operation 13 MAINTENANCE V...

Страница 4: ...IN OUT INCHES 1 1 1 DRAIN SIZE INCHES 3 4 3 4 3 4 OPERATING PRESSURE MAX PSI 125 125 125 OPERATING TEMPERATURE MAX DEG F 110 110 110 MINERAL TANK SIZE DIA X HT 2 INCHES 8X44 10x47 12x52 BRINE TANK SI...

Страница 5: ...5 ft High Pressure Warning If feedwater pressure is known to be above 100 p s i it is strongly recommended that a pressure reducing valve be installed at this point Hard water to Sprinklers and any d...

Страница 6: ...ape is not necessary on the nut connection or caps because of o ring seals Do not use Vaseline oils or other hydrocarbon lubricants oanywhere on the control valve or resin tank assembly A silicon lubr...

Страница 7: ...valve The bypass valve and the control valve are both marked with arrows that indicate the direction of water flow If water lines are reversed resin maybe forced from the water softener and into hous...

Страница 8: ...13 figure 2 8 Press the REGEN button again to cycle the unit to the next cycle Wait for the piston to stop moving and press the REGEN button again Repeat this until the unit is at the home screen The...

Страница 9: ...ime of day Activate Lockout Feature Press DOWN then NEXT then UP then CLOCK in sequence LOCK will briefly ap pear in the display De activate Lockout Feature Press DOWN then NEXT then UP then CLOCK UNL...

Страница 10: ...g takes much less time than comparable products currently on the market Control valve installation is made easy because the distributor tube can be cut 1 2 above to 1 2 below the top of the tank threa...

Страница 11: ...de using DOWN or UP number of days between regeneration 1 to 28 or OFF See Setting Options Table for more detail on setup Press NEXT to go to step 4I Press REGEN to return to previous step STEP 4I STE...

Страница 12: ...for instructions The fth display will show either DP or HOLD if the dP switch is closed If the system has called for a regeneration that will occur at the pre set time of regeneration the words REGEN...

Страница 13: ...usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day To initiate a manual regeneration at the preset delayed regeneration tim...

Страница 14: ...ay will ash on and off which indicates the time of day should be reset and the non rechargeable battery replaced The system will remember the rest Error Message If the word ERROR and a number are disp...

Страница 15: ...Y WATER TO TOP OF TANK CONDITIONED WATER FROM DISTRIBUTOR OUTLET PORT FOR SERVICE WATER flow diagram rinse flow diagram fill CONDITIONED WATER TO REGENERANT TANK SUPPLY WATER OUTLET PORT FOR SERVICE W...

Страница 16: ...ndles point in the direction of flow indicated by the engraved arrows on the control valve Water flows through the control valve during normal operation and this position also allows the control valve...

Страница 17: ...GF SERIESAUTOMATIC WATER CONDITIONERS MAINTENANCE 14 Drive Cap Assembly Downflow Piston Regenerant Piston and Spacer Stack Assembly Front Cover and Drive Assembly t t t 14...

Страница 18: ...1 14 A2242054 Transformer 110V 12V 1 Drive Cap Assembly Downflow Piston Upflow Piston Regenerant Piston and Spacer Stack Assembly Item No Part No Description Quantity 1 A2466034 Spacer Stack Assembly...

Страница 19: ...9 27 28 31 21 Injector Cap Injector Screen Injector Plug O Ring Refill and Refill Port Plug Drain Line 3 4 Proper flow washer orientation directs water flow towards the washer face with rounded edge F...

Страница 20: ...Washer 1 7 gpm for 3 4 A2253081 Drain Flow Washer 2 2 gpm for 3 4 A2253082 Drain Flow Washer 2 7 gpm for 3 4 A2253085 Drain Flow Washer 3 2 gpm for 3 4 A2253086 Drain Flow Washer 4 2 gpm for 3 4 A2253...

Страница 21: ...mplete Specify Model A2042018 2 Brine Tank w Cover A2071005 3 Brine Well A2072003 4 Brine Well Cap A2250003 5 Overflow Elbow A2118010 6 Brine Tube w Air Check B1020001 7 Brine Line Hose w Inserts A200...

Страница 22: ...95069 Nut 1 Quick Connect 1 37 A2360039 Meter Assembly 1 38 A2100027 Turbine Assembly 1 39 use item 51 O Ring 215 Use Valve O ring Kit 1 40 A2287077 Meter Plug Assembly Time clock option 1 Item 37 inc...

Страница 23: ...395009 Bypass Handle 2 47 A2104036 Bypass Rotor Seal Retainer 2 48 use item 52 O Ring 135 use Bypass Valve Kit 2 49 use item 52 O Ring 112 use Bypass Valve Kit 2 50 use item 52 O Ring 214 use Bypass V...

Страница 24: ...n Quantity 1 A2095069 Nut 1 Quick Connect 2 2 A2453012 Split Ring 2 3 A2077178 O Ring 215 2 4 A2569008 Fitting 3 4 1 PVC Solvent 90 2 Order No A2435072 Optional Description Fitting 3 4 Brass Sweat Ass...

Страница 25: ...been ser viced b Foreign matter is lodged in control valve c High drive forces on piston d Control valve piston not in home position e Motor not inserted fully to engage pinion motor wires broken or d...

Страница 26: ...ion b Meter connection disconnected c Restricted stalled meter turbine d Defective meter e Defective PC board f Set up error a Power has been out more than two hours the transformer was unplugged and...

Страница 27: ...GF SERIESAUTOMATIC WATER CONDITIONERS NOTES...

Страница 28: ...8 569 G F R2...

Отзывы: