“GF” SERIES AUTOMATIC WATER CONDITIONERS
OPERATION
9
MA Manual
Page 21
User Display Settings
When the system is operating, several displays may be shown.
Pressing NEXT will alternate between the displays. One of the
displays is the current time of day. CAPACITY REMAINING
is the gallons that will be treated before the system goes through
a regeneration cycle. Pressing DOWN while in the Capacity
Remaining display will decrease the capacity remaining in
10 gallon increments and will also increase the volume used
impacting the recorded values in Diagnostics Steps 3D, 4D
and 5D and Valve History, Step 4VH. DAYS TO A REGEN
is the number of days left before the system goes through a
regeneration cycle. Pressing UP or DOWN while in this screen
will temporarily increase or decrease the displayed value by 1 day.
Another display shows the current treated water
ow rate through
the system. Contact information will be displayed if it was edited.
For concerns with phone number or banner text displays, contact
OEM for instructions. The
fth display will show either DP or
HOLD if the dP switch is closed. If the system has called for a
regeneration that will occur at the pre-set time of regeneration,
the words REGEN TODAY will alternate with the header on the
display. If a water meter is installed, GPM
ashes (and alternates
with the
ow rate) on the display when water is being treated (i.e.
water is
owing through the system). If Salt Level Monitor has
be
en
set to ON in Step 16S, the Salt Level screen will appear. To
adjust the salt level, press CLOCK, and use UP or DOWN to set
the current value. The salt level is adjustable from 0 to 500 lbs. in
10 lb. increments.
GPM and
ow rate
will
ash while water
is being treated.
DELAYED RINSE+FILL PENDING will be displayed whenever a zero-capacity tank has
transferred to an off-line state and is currently waiting to initiate the second portion of a
regeneration cycle. Viewed only when Delayed Rinse and Fill is set to ON.
REGEN PENDING will be displayed in Alternator Systems whenever a unit is waiting to
initiate the
rst cycle step of regeneration.
STAND BY will be displayed in Alternator Systems when a valve is in Standby state.
NOTE: SALT LEVEL screen
only appears if programmed.