“GF” SERIES AUTOMATIC WATER CONDITIONERS
OPERATION
8
Page 20
MA Man u al
Installer Display Settings
STEP 1I
STEP 1I - Press NEXT and UP simultaneously for 3 seconds.
STEP 2I
STEP 2I – Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per
gallon using DOWN or UP. The default is 20 with value ranges from 1 to 150 in 1 grain increments.
Note: The grains per gallon can be increased if soluble iron needs to be reduced. This display will not
show if “FILTERING” is selected in Step 2F or if ‘AUTO’ is not selected in Set Volume Capacity in
OEM Softener System Setup. Press NEXT to go to step 3I. Press REGEN to exit Installer Display
Settings.
STEP 3I
STEP 3I – Day Override: When volume capacity is set to “OFF”, sets the number of days between
regenerations. When volume capacity is set to AUTO or to a number, sets the maximum number of
days between regenerations. If value set to “OFF”, regeneration initiation is based solely on volume
used. If value is set as a number (allowable range from 1 to 28) a regeneration initiation will be
called for on that day even if suf
cient volume of water were not used to call for a regeneration. Set
Day Override using DOWN or UP:
• number of days between regeneration (1 to 28); or
• “OFF”.
See Setting Options Table for more detail on setup. Press NEXT to go to step 4I. Press REGEN to
return to previous step.
STEP 4I
STEP 4I – Next Regeneration Time (hour): Set the hour of day for regeneration using DOWN
or UP. AM/PM toggles after 12. The default time is 2:00 AM. This display will show “REGEN
IMMEDIATE ON ZERO GAL” if “IMMEDIATE” is selected in Set Regeneration Time Option in
OEM Softener System Setup Step 9S or OEM Filter System Setup Step 8F. Press NEXT to go to step
5I. Press REGEN to return to previous step.
STEP 5I
STEP 5I – Next Regeneration Time (minutes): Set the minutes of day for regeneration using DOWN
or UP. This display will not be shown if “IMMEDIATE” is selected in Set Regeneration Time Option
in OEM Softener System Setup Step 9S or OEM Filter System Setup Step 8F. Press NEXT to go to
Step 6I. Press REGEN to return to previous step.
RETURN TO NORMAL MODE
STEP 6I – Energy Saver operation. When set to OFF, the display backlight is always on. When set
to ON, the display backlight will go off after 5 minutes of no keypad activity. A valve error or salt
level alert will activate the display backlight, and prevent deactivation until the error or alert is reset
by the user. Press NEXT to exit Installer Display Settings. Press REGEN to return to the previous
step.