manualshive.com logo in svg
background image

UM_EN

Part No.: 1730015_02

HVA/HVM

USER MANUAL

Содержание HVA

Страница 1: ...UM_EN Part No 1730015_02 HVA HVM USER MANUAL ...

Страница 2: ...ATION AND START UP 6 Positioning 6 Start up procedure 6 Adjusting water temperature 7 Dispensing hot water 7 CLEANING AND CARE 8 ERROR MESSAGES 9 PROGRAMMING 10 Set machine for manual water filling 10 DIMENSION SKETCH 11 HVA HVM 11 IMPORTANT INFO CAUTION INFO More INFO INFO Some important information may appear in textboxes seen below Note ...

Страница 3: ...It will cause material damage to the machine Do not try to open the machine or repair it in any way To avoid danger only have the machine repaired in a technical workshop Service Centre or by a qualified person Remove the mains cable from the socket when the machine is not in use for longer periods To do this pull the plug not the cable This appliance must be placed in a horizontal position which ...

Страница 4: ...olume 7 5 Litres 7 5 Litres Power supply 220 230VAC 1N 2200W 50 60Hz 380VAC 3N 6600W 50 60Hz Cold water connection External thread External thread Capacity 18 litres hour 67 litres hour Water purification filter Option Option Filling and heating time 16 5min 6min MODEL NAME WEIGHT HVA HVM 1 phase 9 kg HVA HVM 3 phase 10 kg ...

Страница 5: ...5 HVA HVM OVERVIEW OF COMPONENTS Hot Water Tap Display Temperature Adjustment Buttons Drip Tray Insert Drip Tray Power Switch Water Connection BACK FRONT ...

Страница 6: ...r s responsibility according to instruction and advice from the supplier In areas with high level lime problem a descaling filter should be mounted Insert the power plug in a separately earthed wall socket See fig C Turn on the machine using the power switch See fig B that is located at the back of the machine The machine will now start to fill up with water and then heat the water The display wil...

Страница 7: ...t water temperature by pressing the buttons on membrane switch Max temperature 96ºC Min temperature 70ºC Place a glass or decanter under the hot water tap A Pull down the tap handle to start dispensing water B Release tap handle to stop dispensing Increase the temperature Reduce the temperature ...

Страница 8: ...8 HVA HVM Exterior cleaning when necessary CLEANING AND CARE To clean the exterior of the machine use a soft cloth and liquid cleaning agent that is non abrasive ...

Страница 9: ...onnection Restart machine SHOWN ONTHE DISPLAY POSSIBLE FAULT POSSIBLE SOLUTION Temperature sensor out of range Temperature sensor is broken Cable loose 50 C 1050 C Replace temperature sensor Check cables Heating time too long Solid state broken Element broken Overheating guard tripped or broken Restart the machine Replace element Replace solid state Check overheating protection The installation wo...

Страница 10: ...he display will show T1 change the type of machine with buttons B or C T1 HVA automatic T2 HVM manual Confirm the choice by holding down the buttons B and C at the same time for approximately 5 seconds A A D E Use a decanter to fill up the water tank to the long sensor pin A Keep button B pressed while turning on the power switch D B C ...

Страница 11: ...11 HVA HVM DIMENSION SKETCH Model A B C D E HVA HVM 1 phase 500mm 225mm 410mm 240mm 210mm HVA HVM 3 phase 500mm 225mm 410mm 240mm 210mm E A B D C HVA HVM ...

Страница 12: ...sued without delay The affected equipment may not be used during awaiting service if there is any risk that the damage or defect would worsen The warranty will not cover consumption supplies such as glassware normal maintenance such as cleaning of filters contaminations in water lime incorrect voltages pressure or adjustment of water amounts The warranty will not cover damages of defects caused by...