4
Extreme temperature conditions
Temperature (ºC)
Reduction of Working Load Limit
-40º to 200ºC
No reduction
Temperatures below -40° or
above 200º C not allowed
Surface treatment
Note!
Hot-dip galvanising or plating is not allowed without control from
the manufacturer.
Severe environments
Lifting points must not be used in alkaline (> pH10) or acidic conditions
(< pH6).
Regular comprehensive examinations must be carried out when used
in severe or corrosive environments. In uncertain situations consult your
Gunnebo Industries distributor.
Protect yourself and others
• Before each use, the lifting point should be checked for obvious
damage or deterioration.
• Know the weight of the load and its centre of gravity.
• Ensure the load is ready to move and that no obstacles will obstruct the
lifting.
• Check the conformity of the load with the Working Load Limit.
• Prepare the landing site.
• Never overload and avoid shock loading.
• Never use an improper configuration.
• Never use a worn or damaged lifting point.
• Do not ever ride on the load.
• Do not ever walk or stand under the suspended load.
• Take into consideration that the load may swing or rotate.
• Watch your feet and fingers while loading/unloading.