General Considerations
Mounting Template
A U-shaped bracket suitable for mounting the sensor should have the dimensions shown on the
right.
Sensor Orientation
Where possible the sensor should be mounted on the centre line of the vessel. It is recommended
that the centre connector and the rear mounting point be on - or parallel to - the centre line of the
vessel (see below).
Sensor Clearance
To facilitate 360° antenna rotation, a cylindrical space of 1400mm diameter with a vertical depth of
300mm around the centre of the rotating antenna should be free from any obstructions.
Sensor on - or
parallel to - the
vessel centre line
Clearance is a
minimum of 800mm
to any obstruction
below the sensor.
Clearance
700mm Radius
Vessel centre line
Vertical
Clearance
of 300mm
150mm
150mm
All dimensions in mm
NOT TO SCALE
13