5

expert net control 2101/2151

Security Advise

1

Security Advise

The device must be installed only by qualified personnel according to the following installation and operating instructions. 
The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equipment
that may cause personal injury or material damage.
Check if the power cord, the plug and the socket are in proper condition.
The device can be connected only to 230V AC (50 or 60 Hz) sockets.
Always connect the device to properly grounded power sockets.To connect a Power-over-Ethernet device, use only certified
and CE marked hardware. 
The device is intended for indoor use only. Do NOT install them in an area where excessive moisture or heat is present.
Because of safety and approval issues it is not allowed to modify the device without our permission.
Please note the safety advises and manuals of connected devices, too.
The device is NOT a toy. It has to be used or stored out or range of children.
Packaging material is NOT a toy. Plastics has to be stored out of range of children. Please recycle the packaging materials.
In case of further questions, about installation, operation or usage of the device, which are not clear after reading the manual,
please do not hesitate to ask our support team.

2

Description

expert net control 2101/2151 is a handy little device suitable for different kinds of telecontrolling. In- and output ports on the

device allow to monitor upt  to two sensors  and switch a contact  through a TCP/IP  network.  expert  net  control  2101/2151
makes it possible to monitor and switch from any computer in the same LAN and from the Internet.

For installation just connect the power and network cables to expert net control 2101/2151.

After  the  device  has  received  an  IP  address  every  client  in  the  same  network  is  able  to  switch  the  output  and  control  the
sensors via webinterface. expert net control 2101/2151 offers also features like SNMP and Syslog. 

expert net control 2101/2151 comprises of two sensor interfaces and one switching output.

A watchdog function for the output is implemented.

3

Hardware

3.1

Content of delivery

Included in delivery are:

expert net control 2101/2151

3.2

Connections

1) Status LED

Содержание expert net control 2101/2151

Страница 1: ...2011 expert net control 2101 2151...

Страница 2: ...expert net control 2101 2151 2011 21 04 2011...

Страница 3: ...via webinterface 4 3 1 Configuration Output Ports 8 4 3 2 Configuration IP address 10 4 3 3 Configuration IP ACL 11 4 3 4 Configuration HTTP 11 4 3 5 Configuration Messages 12 4 3 6 Configuration SNMP...

Страница 4: ...4 Table of content expert net control 2101 2151 2011 19 6 3 Technical information 19 6 4 Fabrique settings Chapter 7 Support 20 Chapter 8 Declarations of conformity 21...

Страница 5: ...ing material is NOT a toy Plastics has to be stored out of range of children Please recycle the packaging materials In case of further questions about installation operation or usage of the device whi...

Страница 6: ...unit expert net control 2101 2151 now is booting and shortly after ready for usage 2 Plug the Ethernet cable into the ethernet connector RJ45 of expert net control 2101 2151 and connect it to your Eth...

Страница 7: ...01 2151 and run GBL_Conf exe The program will look automatically for connected devices and will display their network configuration If the displayed IP address accords with the factory settings 192 16...

Страница 8: ...e after a power on of the device can be defined here on off remember last state 4 3 1 3 Initialization delay While this function is enabled the output will reactive after the stated time when it got s...

Страница 9: ...letters When a watchdog reset a power port the watchdog again waits for a first ping reply as stated above 4 3 1 5 1 Enable Watchdog Here you can activate the watchdog for this output 4 3 1 5 2 Watch...

Страница 10: ...he netmask of expert net control 2101 2151 All changes need a restart of the firmware to get valid 4 3 2 4 Gateway Here you can change the standard gateway of expert net control 2101 2151 All changes...

Страница 11: ...istake please activate the bootloader mode of expert net control 2101 2151 start Gbl_Conf exe and deactivate IP ACL You can find more information about configuration of IP ACL or have a look at http w...

Страница 12: ...a maximum lengths of 15 characters Administrators are authorized to switch all ports and to modify the settings of expert net control 2101 2151 and of all ports The username of the admin is admin Use...

Страница 13: ...ou can define the maximum temperature if the sensor measures this temperature the device will generate an alert via SNMP and Syslog 4 3 5 3 Min Temperature Here you can define the minimum temperature...

Страница 14: ...rt net control 2101 2151 Use SNMP only if your network is fitted for 4 3 7 Configuration SNMP Trap Receiver List 4 3 7 1 Enable Traps Here you can activate SNMP traps if enabled expert net control 210...

Страница 15: ...tching of Power Ports You can find more information about configuration of Syslog in chapter Configuration Syslog or have a look at http www gude info wiki 4 3 8 1 Enable Syslog Here you can activate...

Страница 16: ...re 4 3 9 6 Username Enter the username the device should use to log on your e mail server 4 3 9 7 Set new password If your server needs a password for sending e mails you can enter it here 4 3 9 8 Rep...

Страница 17: ...can check the status of the output by the color of the output status LED green enabled red disabled 5 2 2 Batchmode The output of expert net control 2101 2151 can be switched on or switched off for a...

Страница 18: ...ble delay 1 30 sec or 1 30 min After the chosen delay the selected port will be switched off or switched on again auto matically Optionally the device can be accessed by using the perl script EPC_Cont...

Страница 19: ...are listed Select the device that should be updated click on Program DeviceFirmware Update and determine the location of the new firmware Please note The up to date firmware and GBL_Conf exe can be f...

Страница 20: ...mation current drivers and software can be found on http www gude info In case of further questions about installation or operation of expert net control 2101 2151 please have look at www gude info wi...

Страница 21: ...21 expert net control 2101 2151 Declarations of conformity 8 Declarations of conformity...

Страница 22: ...22 expert net control 2101 2151 Declarations of conformity...

Страница 23: ...expert net control 2101 2151 2011 21 04 2011...

Отзывы: