12. FIRE SAFETY
During the installation of the stove the following safety measures are to be followed:
a) In order to ensure suffi
cient thermal insulation, respect the minimum safety
distance from objects or furnishing components fl ammable and sensitive to heat
(furniture, wooden objects, fabrics etc.) and from materials with fl ammable structure. All
the minimum safety distances have to be respected and lower values must NOT be used.
b) In front of the chimney stove there must not be any fl ammable object or building
material, sensitive to heat, at less than 100 cm distance. If the stove is installed on a
foundation made of fl ammable materials, the foundation must be covered with fi reproof
plates.
c) If the product is installed on a fl oor which is not completely fi re resistant, one must
foresee a fi reproof background, for example a steel platform dimensions according to the
local regulations. The platform must stick out 30 cm sideways and 50 cm in front of the
door.
d) No fl ammable components must be present above the stove.
The chimney stove must operate exclusively with the ash drawer inserted. The solid
residue of the combustion (ashes) must be collected in a hermetic container, resistant
to fi re. The stove must never be ignited when there is gas or steam emissions (e.g. glue,
gasoline, etc.). Never deposit fl ammable materials near the stove. During the combustion
there will be a spread of thermal energy which warms up the surfaces, the door, the
fi replace glass, the handles and knobs, the smoke pipe and the front side of the stove.
Please avoid the contact with these parts without gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the fl ue
and will fuel a chimney fi re.
FIRST-AID MEASURES
Should any fi re arise in the stack or in the fl ue:
a) Close the feeding door and the ash drawer door;
b) Close the regulators of combustion air;
c) Extinguish the fi re using carbon dioxide fi re-fi ghting means CO2 or ‘’S’’ dry powder;
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS.
When the fi re has been extinguished, let the fl ue be checked by an expert to fi nd
possible cracks and permeable points.
Содержание THERMO LAVA
Страница 8: ...Picture 4 Scheme of closed system Picture 5 Scheme of open system ...
Страница 19: ......
Страница 20: ......