Page 115
Issue 08/2013
Operation
System restart iMAPLA controller
6.9
System restart iMAPLA controller
In processor-controlled systems, faults may arise when processing
information during processing programs. In this case, the processor system
must be brought into a pre-defined home position. This is achieved via
a “restart”.
For certain faults, a system restart of the
i
MAPLA controller will be necessary.
Carrying out the restart
In the system, the MMI
is supplied with voltage by
the generator
Ö
Establish the system’s readiness for use, page 106.
>
Switch off the drive unit.
>
Wait until the MMI displays goes out, but for at least 45 seconds. It is only
now that it is assumed that the MMI is fully de-energised and the restart
was carried out correctly.
>
Switch the drive unit back on.
In the system, the MMI
is not supplied with voltage by the generator
Ö
External supply, Establish the system’s readiness for use, page 106
>
Switch off the voltage supply for the MMI.
>
Wait until all displays on the MMI have gone out. It is only now that it is
assumed that the MMI is fully de-energised and the restart was carried out
correctly.
>
Switch on the voltage supply for the MMI.