GST-IFP4M Intelligent Fire Alarm Control Panel
Installation and Operation Manual
Page
39
NAC2TROUBLE/DIS
: This LED is enabled when NAC2/AUX output is programmed
as “NAC” (See Fig 4.10). It lights when NAC2 port is fault; it goes out as the fault is
removed. If NAC2 is disabled, the LED flashes.
FIRE ALARM
: Red. It lights when there is an alarm message.
NAC1 ACTIVATED
: Red. It lights when NAC1 outputs; it goes out as
SILENCE
ALARM
key is pressed.
NAC2 ACTIVATED
: Red. It lights when NAC2 outputs; it goes out as
SILENCE
ALARM
key is pressed.
GROUND TROUBLE
: It lights when there is ground trouble; it goes out as the trouble
is removed.
DETECTOR DIRTY
: It lights when the detector is dirty; it goes out as the dirt is
reported.
DELAY MODE
: It lights when the FACP enters delay mode; it goes out as the FACP
exits delay mode.
Warning: The Delay Mode shall NOT be applied to required output fire signaling in
UL864. It may only be used for supplementary process controls.
TEST MODE
: It lights when the FACP enters test mode; it goes out as the FACP
exits test mode.
MAINTENANCE
: It lights when the FACP enters maintenance mode; it goes out
when the maintenance is completed.
FIRE ALARM INFORMATION
: Red. It flashes when an alarm message is not
confirmed. It lights when all alarm messages have been confirmed.
SUPERVISORY INFORMATION
: It flashes when a supervisory message is not
confirmed; it lights when all supervisory messages has been confirmed.
TROUBLE INFORMATION
: If flashes when a fault message is not confirmed. It lights
when all fault messages have been confirmed; it goes out as all fault messages are
cleared.
DISABLE INFORMATION
: It lights when a disabled message exists; it goes out as
the message is disposed.
STATUS INFORMATION
: It lights when any message exists; it goes out as all
messages are disposed.
MANUAL ALARM
: It lights when the
MANUAL ALARM
key is pressed.
ACKNOWLEDGE
: It lights when all real messages have been confirmed. It goes out
as a new message occurs.
SILENCE ALARM
: The LED lights when any NAC is silenced. It goes out when all
silenced NACs are reactivated .
SILENCE BUZZER
: It lights when the buzzer of the FACP is silenced. It goes out as
the buzzer sounds again.
ALL RESOUND
: It lights when
ALL RESOUND
key is pressed. It goes out when any
NAC is silenced again.