GST-IFP4M Intelligent Fire Alarm Control Panel
Installation and Operation Manual
Page
8
1.4.4 P-9981 Zone Display Panel
Zone Display Panel is used to indicate a related zone, or device states of fire, fault and
isolation. Each zone display panel can show 20 zones or devices, and every 2 indicators
for one zone or device. The user can write or print descriptions on a label for a zone, and
then put the label into the transparent box of the zone display panel.
1.4.5 P-9981F Zone Display Panel
Zone Display Panel is used to indicate a related zone, or device states of fire, fault and
isolation. Each zone display panel can show 20 zones or devices, and every 2
indicators(monochromatic led) for one zone or device. The user can write or print
descriptions on a label for a zone, and then put the label into the transparent box of ZCP.
1.4.6 P-9982 Zone Display and Control Panel
Zone Display and Control Panel is used to indicate a related zone, or device states of fire,
fault and isolation. It can also be used to disable, enable, start and stop the related
devices. Each zone display panel can show 20 zones or devices, and every 2
indicators(double color led) and 1 key for one zone or device. The user can write or print
descriptions on a label for a zone, and then put the label into the transparent box of ZCP.
1.4.7 P-9982F Zone Display and Control Panel
Zone Display and Control Panel is used to indicate a related zone, or device states of fire,
fault and isolation. It can also be used to disable, enable, start and stop the related
devices. Each zone display panel can show 20 zones or devices, and every 2
indicators(monochromatic led) and 1 key for one zone or device. The user can write or
print descriptions on a label for a zone, and then put the label into the transparent box of
ZCP.
1.4.8 PR-400 or PR-400B Thermal Printer
PR-400 or PR-400B Thermal Printer is optional. It can be directly connected to the FACP
through RS232. This printer, with its panel embedded, can be installed on the front panel
of the FACP. It can print running record of the FACP
. It’s easy to operate and convenient
for checking.
1.4.9 CA-400-R CA-400-W or CA-400-G Cabinet
Either CA-400-R, CA-400-W or CA-400-G Cabinet is required. The CA-400-R Cabinet is
red, CA-400-W Cabinet is white and the CA-400-G is gray.
1.4.10 P-9983 Fiber-Optical Network Card
P-9983 card is optional for GST-IFP4M control panel, providing two LC single-mode fiber
interfaces. This card provides the same function as P-9966A CAN Class A network card.
Transmission distance is longer when this card is used to network control panels.
1.4.11 P-9956-Modbus Modbus Card
P-9956-Modbus Modbus Card is optional for supplementary use in GST-IFP4M control
panel, providing standard Modbus interface for transmitting logs or history for
maintenance purposes P-9956-Modbus Modbus Card has three types of one interface:
RS232, RS485 or RS422.