Wiring Requirements
If custom wiring is to be used to power the unit in a +12V application the wire must be rated for 30A and
all 4 INPUT terminals wired. The GSSI cable uses 4 x 12AWG stranded conductors and this should be
suitable for 20 feet of cable length.
General Notes about Vehicle Wiring
It is quite common for several pieces of vehicle-mounted equipment to be interconnected by signal cable
in addition to power connections. GSSI recommends that all equipment use a common ground point. This
will minimize the chances of improper operation or damage occurring due to voltage drops around the
vehicle.
Good practice is to use a fused connection box to supply power to several pieces of equipment. In this
case a large cable is used to bring power to the box and all equipment is powered from the box. This
results in all equipment having a common ground point. Be sure to use a cable capable of handling the
current required by all of the connected equipment.
Never connect/disconnect equipment that is running. This can create sparks that can damage all connected
equipment.
Содержание SIR 30
Страница 1: ......
Страница 4: ...Geophysical Survey Systems Inc SIR 30 Manual ...
Страница 6: ......
Страница 90: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 84 ...
Страница 102: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 96 ...
Страница 120: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 114 ...
Страница 122: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 116 ...
Страница 144: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 138 Figure 168 SIR 30 Cable Pin out ...
Страница 145: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 139 Figure 169 Cable Selection Guide ...
Страница 146: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 140 Figure 170 Survey Wheel and Model 10 Marker Pin Out ...
Страница 147: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 141 Figure 171 Serial Port GPS Pin out ...
Страница 148: ...Geophysical Survey Systems Inc SIR 30 Manual MN 93 101 Rev E 142 ...