Geophysical Survey Systems, Inc.
SIR® 20
Manual
MN92-078 Rev F
86
270 MHz (Model 5104)
270 MHz ground coupled antenna. Middle frequency antenna optimized for mid-range profiling.
Range: 150ns
Samples per Scan: 512
Resolution: 16 bits
Number of gain points: 5
Vertical High Pass Filter: 50 MHz
Vertical Low Pass Filter: 750 MHz
Scans per second: 100
Transmit Rate: 100 KHz
200 MHz (Model 5106)
200 MHz ground coupled antenna. Lower frequency antenna optimized for mid-range profiling.
Pulse duration is 5 ns.
Range: 100ns
Samples per Scan: 512
Resolution: 16 bits
Number of gain points: 5
Vertical High Pass Filter: 50 MHz
Vertical Low Pass Filter: 600 MHz
Scans per second: 100
Transmit Rate: 100 KHz
100 MHz (Model 3207)*
100 MHz ground coupled antenna. Low frequency for deeper profiling. Pulse duration is 10 ns.
Range: 500ns
Samples per Scan: 512
Resolution: 16 bits
Number of gain points: 5
Vertical High Pass Filter: 25 MHz
Vertical Low Pass Filter: 300 MHz
Scans per second: 16
Transmit Rate: 50 KHz
*not available for sale in the United States