English (GB)
88
35
Gas in pump head, deaerating
problem
124
Run capacitor, low (single-phase
motors)
215
Soft pressure build-up time-out
36
Discharge valve leakage
125
Signal fault, outdoor temperature
sensor
216
Pilot pump alarm
37
Suction valve leakage
126
Signal fault, air temperature
sensor
217
Alarm, general-purpose sensor
high
38
Vent valve defective
127
Signal fault, shunt relative
pressure sensor
218
Alarm, general-purpose sensor low
39
Valve stuck/defective
128
Strainer clogged
219
Pressure relief not adequate
40
Undervoltage
144
Motor temperature 3 (Pt100,
t_mo3)
220
Fault, motor contactor feedback
41
Undervoltage transient
145
Bearing temperature high (Pt100),
in general or top bearing
221
Fault, mixer contactor feedback
42
Cut-in fault (dV/dt)
146
Bearing temperature high (Pt100),
middle bearing
222
Time for service, mixer
45
Voltage asymmetry
147
Bearing temperature high (Pt100),
bottom bearing
223
Maximum number of mixer starts
per hour exceeded
48
Overload
148
Motor bearing temperature high
(Pt100) in drive end (DE)
224
Pump fault (due to auxiliary
component or general fault)
49
Overcurrent (i_line, i_dc, i_mo)
149
Motor bearing temperature high
(Pt100) in non-drive end (NDE)
225
Communication fault, pump
module
50
Motor protection function, general
shutdown (MPF)
150
Fault (add-on) pump module
226
Communication fault, I/O module
51
Blocked motor/pump
151
Fault, display (HMI)
227
Combi event
52
Motor slip high
152
Communication fault, add-on
module
228
Night flow max. limit exceeded
53
Stalled motor
153
Fault, analog output
229
Water on floor
54
Motor protection function, 3 sec.
limit
154
Communication fault, display
230
Network alarm
55
Motor current protection activated
(MCP)
155
Inrush fault
231
Ethernet: No IP address from
DHCP server
56
Underload
156
Communication fault, internal
frequency converter module
232
Ethernet: Auto-disabled due to
misuse
57
Dry running
157
Real-time clock out of order
233
Ethernet: IP address conflict
58
Low flow
158
Hardware circuit measurement
fault
234
Backup pump alarm
59
No flow
159
CIM fault (Communication
Interface Module)
235
Gas detected
60
Low input power
160
GSM modem, SIM card fault
236
Pump 1 fault
64
Overtemperature
161
Sensor supply fault, 5 V
237
Pump 2 fault
65
Motor temperature 1 (t_m or t_mo
or t_mo1)
162
Sensor supply fault, 24 V
238
Pump 3 fault
66
Temperature, control electronics
(t_e)
163
Measurement fault, motor
protection
239
Pump 4 fault
67
Temperature too high, internal
frequency converter module (t_m)
164
Signal fault, LiqTec sensor
240
Lubricate bearings (specific
service information)
68
External temperature/water
temperature (t_w)
165
Signal fault, analog input 1
241
Motor phase failure
69
Thermal relay 1 in motor (e.g.
Klixon)
166
Signal fault, analog input 2
242
Automatic motor model recognition
failed
70
Thermal relay 2 in motor (e.g.
thermistor)
167
Signal fault, analog input 3
243
Motor relay has been forced
(manually operated/commanded)
71
Motor temperature 2 (Pt100,
t_mo2)
168
Signal fault, pressure sensor
244
Fault, On/Off/Auto switch
72
Hardware fault, type 1
169
Signal fault, flow sensor
245
Pump continuous runtime too long
73
Hardware shutdown (HSD)
170
Signal fault, water-in-oil (WIO)
sensor
246
User-defined relay has been forced
(manually operated/commanded)
74
Internal supply voltage too high
171
Signal fault, moisture sensor
247
Power-on notice (device/system
has been switched off)
75
Internal supply voltage too low
172
Signal fault, atmospheric pressure
sensor
248
Fault, battery/UPS
76
Internal communication fault
173
Signal fault, rotor position sensor
(Hall sensor)
249
User-defined event 1
77
Communication fault, twin-head
pump
174
Signal fault, rotor origo sensor
250
User-defined event 2
Code Description
Code Description
Code Description
Pumpland.ru
Содержание CIM 200