Iron / manganese removal
Demanganisation system GENO-mat MN-Z
Order no. 095 153 048-inter Edited by: nkes-mrie G:\BA-153048-INTER_095_GENO-MAT_MN-Z.DOCX
7
3.3
Intended use
The system may only be used for the purpose outlined in the product
description (chapter C). The guidelines in this operation manual as
well as the applicable local guidelines concerning drinking water pro-
tection, accident prevention and occupational safety must be ob-
served.
In addition, intended use also implies that the system may only be
operated when it is in proper working order.
Any errors must be eliminated at once.
3.4
Protection from
water damage
Warning!
To properly protect the installation site from water dam-
age:
a) a sufficient floor drain system must be available or
b) a water stop device (see chapter C Accessories) must be in-
stalled.
Warning! Floor drains that discharge to a lifting system will not work
in case of a power failure.
3.5
Indication of
specific dangers
Danger due to electrical energy!
Do not touch electrical compo-
nents with wet hands! Disconnect the system from the mains before
starting work on electrical system components! Have qualified ex-
perts replace damaged cables immediately.
Danger due to mechanical energy! System components can be sub-
ject to overpressure. Risk of injuries and damage to property due to
escaping water and unexpected movement of system parts.
Check pressure pipes regularly. Depressurise the system before
starting repair or maintenance work on the system.
Hazardous to health due to contaminated drinking water!
The
system should be installed by a specialist company only. Strictly ad-
here to the operation manual! Ensure that there is sufficient flow,
and observe the relevant guidelines when starting up the system af-
ter extended periods of standstill. Perform inspections and mainte-
nance at the intervals specified!
Note:
By concluding a maintenance contract, you ensure that all of
the required tasks are performed on time. The intermediate inspec-
tions can be performed in-house.