Operating Instructions: LUB‐M
36
11) Service: Lubricus M
Lubricus M ist is designed for minimum quantity lubrication.
A service for the verification of the performance of Lubricus M recommended. Service interval is 65,000 cycles per pump unit.
65,000 cycles correspond to 10.000 cm³ lubricant.
11.1 Readout of the device memory
The number of cycles can be determined by reading the device memory:
Touch for 5s the operating pad (ENTER) with the programming key. Then remove the programming key. The display shows in sequence
the number of cycles for every installed pump unit. The cycles are counted to 65,535.
.
Thereafter an overflow occurs. Number 1 appears in the display. The cycles are counted again, starting with number 1. 65.535 must be
added to the displayed number. A service of the pump unit is strongly recommended in order to ensure the performance of Lubricus M.
The only other service required is the change of grease cartridge.
P1 = 17.853 cycles