Select pump body (P1-P5)
via SELECT
indicated by a green LED on the control panel.
Confirmation with ENTER
Input pause time (H: TIME)
via SELECT
max. 240 h possible
Confirmation with ENTER
Input number of cycles (C: Cycle)
via SELECT,
max. 30 possible
Confirmation with ENTER
SELECT: Change settings
ENTER: Confirmation of all changes
If no interaction takes place for a period,
the device automatically returns to the
previous display mode
Tim
e cont
ro
l
5.2 Input pause time and amount of lubricant
The following settings can be made for each pump body.
H: TIME (pause time):
time between the lubrication intervals in hours (1 to 240 h are possible)
Attention: If H: TIME = 0 it is not possible to input cycles.
C: CYCLE (number of cycles)
= amount of lubricant per interval (1 to 30 possible, 1 cycle = 0,15 cm³)
Pump units can be turned off by setting C: CYCLE = 0
Factory setting for every pump unit: H: TIME = 4h, C: CYCLE = 1
step-by-step approach:
Select other pump unit or timeout: exit the menu.