INSTALL ANTI-BILLOW ROPES (ROLL-UP & DROP-DOWN SIDES)
ANTI-BILLOW ROPE INSTALLATION
TO PREVENT DAMAGE AND POSSIBLE INJURY, INSTALL ANTI-BILLOW ROPES
IN SHORT LENGTHS
ALONG EACH SIDE. DO NOT INSTALL AS A SINGLE LENGTH TIED AT EACH END. DOING SO WILL RESULT
IN A LOOSE SIDE PANEL IF SINGLE ROPE BREAKS.
CONSULT THE SIDE PROFILE DIAGRAM FOR YOUR
FRAME LENGTH IN THE QUICK START SECTION FOR ROPE PATTERN AND ROPE HOOK LOCATIONS.
Follow these general steps to attach the 117063 rope hooks and
install the anti-billow ropes:
1. Determine the location of rope hooks and the number of anti-
billow ropes for each side using the Side Profile diagram in the
Quick Start section for your frame length.
2. Attach the 117063 rope hooks using wood screws for wood
and Tek screws for metal. Be sure to note where one rope
stops and the next rope begins.
3. Take the CC5525 (1/4") rope and install it in short lengths
along each side. Pull tight to keep panels in place.
4. Test the operation of the roll-up or drop-down side.
5. Repeat to install the anti-billow rope for the remaining side
once the panel is installed.
6. With all anti-billow ropes installed, continue with the next page.
C
D
ROPE
#1
ROPE
#2
A
A
B
B
C
D
NOTE:
In those
instances when
two ropes
terminate at the
baseboard or
lower position (D),
install the rope
snaps and rope
as shown in these
photos.