OM/SM-HY-3E & HY-5E(CE)
9
3.
Drain Connection
Level the steamer front to back, or even pitch it
slightly to the rear by adjusting the bullet feet on
the stand or cabinet base.
A two inch (50mm) ID hose should be attached
to the drain pipe and elbow supplied.
WARNING
:
DO NOT CONNECT THE DRAIN DIRECTLY TO A
BUILDING DRAIN. BLOCKING THE DRAIN IS
HAZARDOUS.
There must be at least one-half inch free air gap
between the end of the hose and the building
drain. The free air gap should be as close as
possible to the unit drain. There must also be no
other elbows or other restrictions between the
unit drain and the two inch free air gap.
CAUTION
DO NOT USE PLASTIC PIPE. DRAIN MUST BE
RATED FOR VERY HOT WATER.
Install the drain line with a constant downward pitch.
IMPORTANT: Do not allow water traps in the
line. A trap can cause pressure build-up in the
cavity, which may cause the door gasket to leak.