OM/SM-HY-3E & HY-5E(CE)
33
3.
If the door has been reversed and the switch
must be removed and replaced, refer to the
top panel removal in Section B and then
remove the switch as above.
T. Door Reversing Procedures
Refer to Sections S and V for additional instructions.
1.
Turn off steamer power and allow steamer to
cool.
2.
To remove door, support door while
removing hinge-to-steamer bolts.
3.
Place door with hinge on a flat, clean table
(or similar support), with the gasket facing
up.
Be careful not to scratch door surface.
4.
Note and record distance between lock nut
and end of door locking pin (bullet). This
information will be needed during bullet
installation in Step 6.
5.
Loosen lock nut, then remove door bullet
and lock nut.
6.
Coat bullet threads with a few drops of
Locktite 222. Install bullet and lock nut
directly across steamer cavity from old bullet
location. Install these two items so that lock
nut to end of bullet distance is approximately
the same as measured in Step 4.
7.
Remove the two screws from above and
below the old bullet location and install them
above and below the new bullet location.
8.
Remove screws and U-channel from the
door. Take magnet and block assembly from
present location and place it at the opposite
end of the door channel, with magnet facing
outward from the door.
9.
Remove door handle screws and door
handle from cam..
10. Apply NEVER-SEEZ high temperature (1800
degrees F) anti-seize and lubricating
compound to the cam and a few drops of
Locktite 242 to door handle screw threads.
11. Turn handle and cam 180-degrees from
their original positions and install them on
the door with screws. Be sure handle and
cam move smoothly.
12. Be sure door handle and door cam is in the
DOWN position. Turn U-channel 180-
degrees from its original position, hold door
spring in U-channel open with a screwdriver
or similar tool, and install U-channel.
13. Check operation of the cam. Push up on the
door handle and check if the spring opens. If
the spring does not open, cam and spring
are NOT correctly aligned and problem must
be corrected.
14. Apply a light amount of Locktite 242 to
screws, then install screws.
15. Apply Locktite 242 to the hinge-to-steamer
bolts, then install door and hinge mounting
bolts. Do
NOT
tighten mounting bolts at this
time.
16. Align door to steamer. Refer to Section R.
17.
IMPORTANT
. When the door is reversed,
the alternate door switch (installed at time of
manufacture) must be connected to the
circuit.
18. From the right side access to the upper
portion of the steamer, disconnect the two
leads of the door switch.
19. The wires for the alternate door switch may
be found under the cavity. Connect the two
wires from the switch to the electrical board.
20. Close steamer door and operate steamer. If
fan does not operate, check location of door
magnet and try operation again. If fan
operation problem still exists, refer to
Section S.
21. With the door closed and the steamer in the
ON position, or with the timer running, the
GREEN/READY light should come on.
22. Allow steamer to operate for approximately
five minutes, and then check for leaks. If
there are no leaks, the steamer is ready for
operation. If there are leaks around the door,
recheck door alignment, and if necessary,
door gasket installation.
U. Door Gasket
P/N 094147
1.
To install, turn off steamer, and allow to cool.
2.
Remove the door using one of the following:
a) Support door weight and remove hinge
pin, or