OM/SM-HY-3E & HY-5E(CE)
28
Control Transformer
Electric Heater Assembly - High Limit Thermostat
Switch Box Mounted Above
2.
Note the position and identity of the
terminals and then remove them from the
control transformer.
3.
With a 5/16 inch nutdriver, remove the four
10-32 screws holding the control transformer
to the service tray.
Note: Do not lose lock washers at the ground
wire.
4.
Remove control transformer from the service
tray.
To Install:
5.
Install the control transformer in the service
tray.
6.
Fasten the control transformer to the service
tray with four 10-32 screws using a 5/16 inch
nutdriver.
Note: Ground terminal between lock
washers.
7.
Reattach terminals to control transformer.
WARNING
DISCONNECT THE POWER SUPPLY BEFORE
BEGINNING ANY SERVICE PROCEDURE.
L.
Gasket
Heater Element
P/N 042366
P/N 123102 (240 Volt)
High Limit Thermostat
P/N 122009
1.
Turn off all power to the steamer.
2.
Remove the six terminals and two plugs
from the heating element.
3.
With a 1/2 inch socket wrench, remove the
four nuts and lockwashers holding assembly
to generator.
4.
Carefully slide the assembly about 2 inches
out of the steam generator.
5.
Remove the two 6-32 self tapping sheet
metal screws from the underside of the
thermostat switch.
6.
Remove the two terminal wires attached to
the thermostat Electric Heater Assembly
switch.
Содержание HY-3E
Страница 19: ...OM SM HY 3E HY 5E CE 19 Parts List Model HY 5E https appliancetechmanuals com ...
Страница 21: ...OM SM HY 3E HY 5E CE 21 Electrical Schematics HY 3E https appliancetechmanuals com ...
Страница 22: ...OM SM HY 3E HY 5E CE 22 Electrical Schematics HY 5E https appliancetechmanuals com ...