OM/SM-HY-3E & HY-5E(CE)
25
Steam Hose is Mounted Above the Fan Motor,
Clean Hose is Mounted Below
2.
Remove the large steam hose by loosening
the hose clamp with a 5/16 inch nutdriver
and then removing the hose from the steam
port collar.
3.
Remove the 3/4 inch clean hose by
loosening its hose clamp with a 5/16 inch
nutdriver and then removing the hose from
the steam port collar.
4.
With a flat blade screwdriver, remove the
two 6-32 screws which hold the thermostat
to the steam port.
5.
With a sharp knife or scissor, cut the foil
thermal blanket. Then fold back the foil
blanket to reveal the two 1/4-20 kep nuts,
which hold the steam port to the cavity wall.
6.
With a 7/16 inch nutdriver remove the two
kep nuts.
7.
Remove the steam port from the threaded
studs.
To Install
:
8.
Apply RTV Clear Silicone Sealant to the
groove of the steam port (or use gasket P/N
099250), then insert the steam port on the
two threaded studs and fasten the two kep
nuts with a 7/16 inch nutdriver. Wipe away
excess sealant from the cavity.
9.
Mend the foil thermal blanket, where cut,
with aluminum foil duct tape.
10. Fasten the thermostat with two 6-32 screws.
Apply heat sink compound to the bottom of
thermostat and to the threads of the screws
to prevent leaks. See Section E.
11. Install the 3/4 inch clean hose on the steam
port and fasten with hose clamp.
12. Install large steam hose to steam port and
fasten with hose clamp.
WARNING
DISCONNECT THE POWER SUPPLY BEFORE
BEGINNING ANY SERVICE PROCEDURE.
G.
Cavity Hose Assembly
Steam Hose (HY-3E) P/N 123867
Steam Hose (HY-5E) P/N 126008
Clean Hose (HY-3E) P/N 101641
Clean Hose (HY-5E) P/N 125954
There is one
steam
hose installed
over
the motor
connecting the steam generator to the cavity. There
is a
clean
hose installed
under
the motor which
connects the steam generator with the cavity. Either
hose may be replaced using the following method:
1.
Shut off power to the steamer.
2.
Using a 5/16 inch nutdriver, loosen the hose
clamp where the hose is attached to the
steam port. Turn and pull the hose to
remove it from the hose collar.
3.
Using a 5/16 inch nutdriver, loosen the hose
clamp where the hose is connected to the
steam generator. Turn and pull the hose to
remove it from the hose collar.
4.
The hose may be removed.
IMPORTANT. Make sure that the correct part
(and part number) is being used. The hoses are
similar in appearance but are not the same!
Install steam hose over the motor. The clean
hose must be installed under the motor to allow
cleaning liquids to enter the generator.