Extension Cords
Since this machine must be permanently con-
nected to the power supply, an extension cord
cannot be used.
Figure 4. Typical setup of a permanently
connected machine.
Power
Source
Locking
Disconnect Switch
Machine
Ground
Ground
Conduit
Conduit
Connection Type
A permanently connected (hardwired) power sup-
ply is typically installed with wires running through
mounted and secured conduit. A disconnecting
means, such as a locking switch (see following
figure), must be provided to allow the machine
to be disconnected (isolated) from the power
supply when required. This installation must be
performed by an electrician in accordance with all
applicable electrical codes and ordinances.
Serious injury could occur if you connect
machine to power before completing setup
process. DO NOT connect to power until
instructed later in this manual.
Grounding Instructions
In the event of a malfunction or breakdown,
grounding provides a path of least resistance
for electrical current to reduce the risk of electric
shock. A permanently connected machine must
be connected to a grounded metal permanent wir-
ing system; or to a system having an equipment-
grounding conductor. All grounds must be verified
and rated for the electrical requirements of the
machine. Improper grounding can increase the
risk of electric shock!
Avoid using a static phase converter to supply
3-Phase power for this machine, as it could dam-
age or decrease the life of sensitive electrical
components. If you must use a phase converter,
only use a rotary phase converter that is sized
at least 50% larger than the HP rating of this
machine. If using a phase converter to supply
power, only connect the manufactured leg or "wild
wire" to the "L3" terminal (see location on
Page
51). The L3 terminal can handle power fluctua-
tions because it is wired directly to the motor.