-60-
Model G0715P (Mfg. 4/11+)
Symptom
Possible Cause
Possible Solution
Blade is not aligned
with miter slot or
fence.
1. Blade is warped.
2. Table top is not parallel to blade.
3. Fence is not parallel to blade.
1. Replace blade (
Page 31).
2. Make table parallel to blade (
Page 63).
3. Make fence parallel to blade (
Page 68).
Blade does not
reach 90°.
1. 90° stop collar is out of adjustment.
2. Sawdust stuck on stop collar.
1. Adjust 90° stop collar (
Page 61).
2. Clean sawdust off stop collar.
Blade hits insert at
45°.
1. 45° stop collar is out of adjustment.
2. Sawdust stuck on stop collar.
3. Slot in insert is inadequate.
4. Table out of alignment.
5. Blade position is incorrect.
1. Adjust 45° stop collar (
Page 61).
2. Clean sawdust off stop collar.
3. File or mill the slot in the insert.
4. Align blade to the table (
Page 63).
5. Adjust blade position.
Board binds or
burns when feeding
through table saw.
1. Dull blade.
2. Blade is warped.
3. Fence is not parallel to blade.
4. Table top is not parallel to blade.
1. Replace blade (
Page 31).
2. Replace blade (
Page 31).
3. Make fence parallel to blade (
Page 68).
4. Make table parallel to blade (
Page 63).