3.2 Fitting the lamp
1) Open the lamp cover by loosening the 2 screws (indicated by arrows A) located on the rear
part of the head of the unit (see pictures 1, 2, 3).
2) Clean the lamp with a cleaning towel and fit it carefully in the lamp holder.
Avoid touching the lamp with fingers or dirty towels. Do not shake the lamp or make it clash
against the frame of the unit or any other internal component.
3) Fix the lamp to the lamp holder tightly.
4) Close the lamp cover.
5) The beam may not be even when you install the lamp. This may vary depending on different
lamps shape. For this reason lamp adjustment can be carried out by loosening or turning in the
3 M4 screws (indicated by arrows B) located on the lamp cover (see pict. 3).
3.3 Mounting position
ACROBAT PE 575 can be mounted in any position.
The support plate is fitted with 4 rubber feet that allow a steady position on the floor. The unit
should be installed at a minum distance from flammable objects of 0.5m, so as to make air cir-
culation easy.
3.4 Fixing plate
The base of the unit is provided with 6 M10
thread inserts to allow a steady installation on
every single kind of trussing system as well as
on the wall and on the floor.
Please note that the rubber feet can be removed
for a much more confortable fixing of the unit
by its proper insert.
3.5 Electrical connection
1) Cable the mains plug with a supply cable 3x1.5mm
2
(minimum size).
2) Connect the lantern to a mains supply of 230V - 50/60Hz.
3) Make sure the mains supply unit is correctly grounded.
The power line shall be provided with safety switch. (IN 10A, ID 0,03A).
4) ACROBAT PE 575 is fitted with power factor correction.